Daikin 2MXS50H2V1B manuals
2MXS50H2V1B
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- List of Functions
- Heat Pump Models
- Part 2 Specifications
- Specifications
- duct connected type
- floor standing type
- ceiling mounted cassette type
- Outdoor Units - Cooling Only
- Indoor Units - Heat Pump
- Outdoor Units - Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Printed Circuit Board Connector Wiring Diagram
- Duct Connected Type
- Floor / Ceiling Suspended Dual Type
- Floor Standing Type
- Ceiling Mounted Cassette Type (600×600)
- Outdoor Units
- Part 4 Function and Control
- Main Functions
- Power-Airflow Flaps, Wide-Angle Louvers, Auto-Swing COMFORT AIRFLOW Mode and 3-D Airflow
- Operation Starting Control
- Fan Speed Control for Indoor Units
- Program Dry Function
- Automatic Operation
- Thermostat Control
- Night Set Mode
- ECONO Mode
- AREA INTELLIGENT EYE (FTXS)
- INTELLIGENT EYE (ATXS, FTXG, ATXG, CTXG)
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Other Functions
- weekly timer operation
- Function of Thermistor
- Cooling Only Model
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- compressor protection function
- Discharge Pipe Temperature Control
- Freeze-up Protection Control
- Fan Control
- Defrost Control
- Electronic Expansion Valve Control
- Malfunctions
- Additional Function
- Part 5 Operation Manual
- System Configuration
- Instruction
- remote controller
- adjusting the airflow direction
- adjusting the air flow direction
- comfort airflow operation
- powerful operation
- outdoor unit quiet operation
- econo operation
- intelligent eye operation
- timer operation
- to use on timer operation
- note for multi system
- FTXS, FVXS Series
- comfort airflow and intelligent eye operation
- quiet operation
- FFQ Series
- safety considerations
- installation site
- switch and display on the remote controller
- trouble shooting
- Part 6 Service Diagnosis
- Caution for Diagnosis
- Problem Symptoms and Measures
- Service Check Function
- ARC452 Series
- Troubleshooting
- Indoor Unit PCB Abnormality
- Freeze-up Protection Control or High Pressure Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault
- OL Activation (Compressor Overload)
- Compressor Lock
- DC Fan Lock
- Input Overcurrent Detection
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- DC Voltage / DC Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Overcurrent Detection
- Refrigerant Shortage
- Over-voltage Detection / Low-voltage Detection
- Outdoor Unit PCB Abnormality or Signal Transmission Circuit Abnormality
- Check
- electronic expansion valve check
- four way valve performance check
- thermistor resistance check
- installation condition check
- discharge pressure check
- power transistor check
- hall ic check
- Part 7 Removal Procedure
- Outdoor Unit
- Removal of the Electrical Box
- Removal of the PCB
- Removal of the Sound Blanket
- Removal of the Outdoor Fan / Fan Motor
- Removal of the Thermistors
- Removal of the Compressor
- Removal of the Four Way Valve / Electronic Expansion Valve
- Part 8 Trial Operation and Field Settings
- Pump Down Operation
- Forced Cooling Operation Mode
- Trial Operation
- Indoor Unit - FFQ Series
- Field Settings
- jumper and switch settings
- Maximum Power Input Limitation Setting
- Application of Silicon Grease to a Power Transistor and a Diode Bridge
- Part 9 Appendix
- Piping Diagrams
- heat pump
- Wiring Diagrams
2MXS50H2V1B
Table of contents
- Part 1 List of Functions ................................................................ 1
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- Functions
- Part 2 Specifications
- Indoor Unit
- specifications
- floor standing type
- duct connected type
- ceiling mounted cassette type
- Outdoor Unit
- Part 3 Printed Circuit Board Connector Wiring Diagram
- CTXS15/35K2V1B, FTXS20/25K2V1B
- FTX20/25/35JV1B, FTX20/25/35J2V1B, ATX20/25/35JV1B ATX20/25/35J2V1B
- FVXG25/35/50K2V1B
- FVXS25/35/50FV1B
- FLXS25/35/50BAVMB
- FFQ25/35/50B8V1B, FFQ25/35/50B9V1B
- Wired Remote Controller
- BRC1E51A7
- Wireless Remote Controller
- Part 4 Function and Control
- Part 4 Function and Control
- Function of RA Indoor Unit
- Operation Starting Control
- Airflow Direction Control
- Fan Speed Control for Indoor Unit
- RADIANT Operation
- Program Dry Operation
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- ECONO Operation
- HOME LEAVE Operation
- Area INTELLIGENT EYE Operation
- INTELLIGENT EYE Operation
- Inverter POWERFUL Operation
- Multi-Colored Indicator Lamp / TIMER Lamp
- Brightness Setting of Indoor Unit Display
- Clock Setting
- WEEKLY TIMER Operation
- Other Functions
- Function of SA Indoor Unit
- remote controller
- Thermostat Sensor in Remote Controller
- Freeze Prevention Control
- Hot Start Control (In Heating Operation Only)
- Function of Thermistor
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Temperature Control
- Input Current Control
- Heating Peak-cut Control
- Outdoor Fan Control
- Defrost Control
- Outdoor Electronic Expansion Valve Control
- Malfunctions
- Part 5 Remote Controller
- RA Indoor Unit
- mode button
- FTXS35/42/50K2V1B
- FTXS20/25/35/42/50J2V1B
- ATXS20/25/35/42/50G2V1B
- SA Indoor Unit
- operation mode
- BRC7E530W
- Service Diagnosis
- Part 6 Service Diagnosis
- Table Of Contents
- Troubleshooting with LED
- Problem Symptoms and Measures
- Service Check Function
- arc452 series remote controller
- arc433 series remote controller
- Code Indication on Remote Controller
- Troubleshooting for RA Indoor Unit
- Freeze-up Protection Control or Heating Peak-cut Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (RA Indoor Unit)
- Front Panel Open / Close Fault (FTXG Series Only)
- Troubleshooting for SA Indoor Unit
- Drain Level Control System Abnormality
- Fan Motor (AC Motor) or Related Abnormality
- Drain System Abnormality
- Thermistor or Related Abnormality (SA Indoor Unit)
- Remote Controller Thermistor Abnormality
- Field Setting Abnormality
- Troubleshooting for Outdoor Unit
- Low-voltage Detection or Over-voltage Detection
- Outdoor Unit PCB Abnormality or Signal Transmission Error
- Unspecified Voltage (between Indoor Unit and Outdoor Unit Anti-icing Control in Other Room
- Anti-icing Control for Indoor Unit
- OL Activation (Compressor Overload)
- Compressor Lock
- dc fan lock
- Input Overcurrent Detection
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- DC Voltage / Current Sensor Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Overcurrent Detection
- Check
- Fan Motor Connector Output Check
- Hall IC Check
- Power Supply Waveforms Check
- Outdoor Electronic Expansion Valve Check
- Four Way Valve Performance Check
- Inverter Analyzer Check
- Rotating Pulse Input on the Outdoor Unit PCB Check
- Installation Condition Check
- Outdoor Unit Fan System Check
- Power Module Check
- Part 7 Trial Operation and Field Settings
- Pump Down Operation
- Forced Cooling Operation
- Trial Operation
- SA Indoor Unit - FFQ Series
- Field Settings
- Silicon Grease on Power Transistor / Diode Bridge
- Part 8 Appendix
- Piping Diagrams
- Wiring Diagrams
- Removal Procedure (Booklet No.)
- revision history