SiBE121123_AService Diagnosis 134Part 6Service Diagnosis1. Troubleshooting with LED ...................................................................1361.1 Indoor Unit............................................................................................1361.2 Outdoor Unit .........................................................................................1372. Problem Symptoms and Measures .....................................................1383. Service Check Function ......................................................................1393.1 RA Indoor Unit......................................................................................1393.2 SA Indoor Unit ......................................................................................1484. Code Indication on Remote Controller ................................................1554.1 RA Indoor Unit......................................................................................1554.2 SA Indoor Unit ......................................................................................1554.3 Outdoor Unit .........................................................................................1565. Troubleshooting for RA Indoor Unit.....................................................1575.1 Indoor Unit PCB Abnormality ...............................................................1575.2 Freeze-up Protection Control or Heating Peak-cut Control..................1595.3 Fan Motor or Related Abnormality .......................................................1615.4 Radiant Panel Temperature Rise, Indoor Electronic Expansion Valve(Motor Operated Valve) Abnormality, Freeze-up Protection Control(FVXG Series Only)..............................................................................1655.5 Thermistor or Related Abnormality (RA Indoor Unit)............................1675.6 Front Panel Open / Close Fault (FTXG Series Only) ...........................1686. Troubleshooting for SA Indoor Unit.....................................................1696.1 Indoor Unit PCB Abnormality ...............................................................1696.2 Drain Level Control System Abnormality..............................................1706.3 Fan Motor (AC Motor) or Related Abnormality.....................................1716.4 Drain System Abnormality....................................................................1726.5 Thermistor or Related Abnormality (SA Indoor Unit)............................1736.6 Remote Controller Thermistor Abnormality ..........................................1746.7 Signal Transmission Error(between Indoor Unit and Remote Controller)......................................1756.8 Signal Transmission Error(between MAIN Remote Controller and SUB Remote Controller)........1766.9 Field Setting Abnormality .....................................................................1777. Troubleshooting for Outdoor Unit........................................................1787.1 Refrigerant Shortage ............................................................................1787.2 Low-voltage Detection or Over-voltage Detection................................1807.3 Outdoor Unit PCB Abnormality or Signal Transmission Error ..............1827.4 Unspecified Voltage (between Indoor Unit and Outdoor Unit) /Anti-icing Control in Other Room..........................................................1857.5 Anti-icing Control for Indoor Unit ..........................................................1867.6 OL Activation (Compressor Overload) .................................................1887.7 Compressor Lock .................................................................................1907.8 DC Fan Lock ........................................................................................1917.9 Input Overcurrent Detection .................................................................192