Datalogic Gryphon I GD440X manuals
Gryphon I GD440X
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Manual Conventions
- Technical Support
- About the Reader
- The BC40xx™ Radio Base
- BC40XX UV Counterfeit Detection
- Battery Safety
- Programming the Reader
- SETUP
- Installing the Interface Cable
- Configuring the Base Station
- Changing the Base Station Position
- Connecting the Base Station
- Connecting the Base when Security Pin is Enabled
- linking a bt reader to a pc
- Gryphon™ 2D System and Network Layouts
- Interface Selection
- Customizing Configuration Settings
- Resetting the Product Configuration to Defaults
- Replacing the Battery
- CONFIGURATION USING BAR CODES
- GLOBAL INTERFACE FEATURES
- Baud Rate
- Data Bits
- Parity
- Handshaking Control
- Intercharacter Delay
- beep on not on file
- ACK NAK Options
- ACK Character
- ACK NAK Timeout Value
- ACK NAK Error Handling
- Disable Character
- Keyboard EMULATION Settings
- Country Mode
- Send Control Characters
- Wedge Quiet Interval
- Caps Lock State
- USB Keyboard Speed
- USB Keyboard Numeric Keypad
- Keyboard Settings
- USB-OEM Interface
- USB-OEM Device Usage
- IBM 46XX Interface
- xx Number of Host Resets
- Transmit Labels in Code 39 Format
- Wand Emulation Interface
- Wand Signal Speed
- Wand Idle State
- Label Symbology Conversion
- Data Format
- Global Prefix/Suffix
- Global AIM ID
- set aim id individually for gs
- Label ID
- Individually Set Label ID
- Label ID Symbology Selection − 1D Symbologies
- label id symbology selection
- Advanced Formatting: User Label Edit
- Character Conversion
- Reading Parameters
- Double Read Timeout
- LED AND BEEPER INDICATORS
- Good Read Beep Type
- Good Read Beep Length
- Good Read Beep Volume
- Good Read LED Duration
- SCANNING FEATURES
- Stand Mode Indication
- Stand Operation
- Pick Mode
- Stand Mode Illumination Off Time
- Stand Illumination Control
- Flash On Time
- Aiming Pointer
- Green Spot Duration
- Partial Label Reading Control
- Image Capture
- Corded Stand Beep
- MULTIPLE LABEL READING
- Multiple Labels Ordering by Code Symbology
- D Symbologies
- DISABLE ALL SYMBOLOGIES
- CODE EAN/UPC
- UPC-A
- Expand UPC-A to EAN-13
- UPC-A 2D Component
- UPC-E Check Character Transmission
- Expand UPC-E to EAN-13
- UPC-E Number System Character Transmission
- EAN 13 Enable/Disable
- EAN-13 Flag 1 Character
- EAN-13 2D Component
- EAN 8 Enable/Disable
- EAN 8 2D Component
- UPC/EAN GLOBAL SETTINGS
- UPC/EAN Quiet Zones
- ADD-ONS
- Optional Add-On Timer
- Optional GS1-128 Add-On Timer
- Code 39 Enable/Disable
- Code 39 Check Character Transmission
- Code 39 Start/Stop Character Transmission
- Code 39 Quiet Zones
- Code 39 Set Length 1
- Code 39 Set Length 2
- TRIOPTIC CODE
- Code 32 Check Char Transmission
- CODE 39 CIP (FRENCH PHARMACEUTICAL)
- CODE 39 LAPOSTE
- CODE 128
- Code 128 Check Character Transmission
- Code 128 Sub-Code Exchange Transmission
- Code 128 Length Control
- Code 128 Set Length 1
- Code 128 Set Length 2
- GS1-128 Enable
- CODE ISBT 128
- ISBT 128 Concatenation Mode
- ISBT 128 Dynamic Concatenation Timeout
- I 2 of 5 Enable/Disable
- I 2 of 5 Check Character Calculation
- I 2 of 5 Check Character Transmission
- INTERLEAVED 2 OF 5 CIP HR
- Standard 2 of
- Standard 2 of 5 Check Character Transmission
- Standard 2 of 5 Set Length 1
- Standard 2 of 5 Set Length 2
- INDUSTRIAL 2 OF 5
- Industrial 2 of 5 Check Character Transmission
- Industrial 2 of 5 Set Length 1
- Industrial 2 of 5 Set Length 2
- CODE IATA
- CODABAR
- Codabar Check Character Transmission
- Codabar Start/Stop Character Set
- Codabar Quiet Zones
- Codabar Set Length 1
- Codabar Set Length 2
- ABC CODABAR
- ABC Codabar Dynamic Concatenation Timeout
- ABC Codabar Force Concatenation
- Code 11 Enable/Disable
- Code 11 Check Character Transmission
- Code 11 Set Length 1
- Code 11 Set Length 2
- GS1 DATABAR™ OMNIDIRECTIONAL
- GS1 DataBar™ Omnidirectional 2D Component
- GS1 DATABAR™ EXPANDED
- GS1 DataBar™ Expanded 2D Component
- GS1 DataBar™ Expanded Set Length 1
- GS1 DataBar™ Expanded Set Length 2
- GS1 DATABAR™ LIMITED
- GS1 DataBar™ Limited 2D Component
- Code 93 Enable/Disable
- Code 93 Check Character Transmission
- Code 93 Set Length 1
- Code 93 Set Length 2
- Code 93 Quiet Zones
- MSI Check Character Calculation
- MSI Length Control
- MSI Set Length 1
- MSI Set Length 2
- PLESSEY
- Plessey Check Character Transmission
- Plessey Set Length 1
- Plessey Set Length 2
- D Maximum Decoding Time
- D Structured Append
- Aztec Code
- Aztec Code Set Length 2
- China Sensible Code
- china sensible code set length 1
- China Sensible Code Set Length 1
- Data Matrix
- Data Matrix Length Control
- Data Matrix Set Length 1
- Maxicode
- Maxicode Length Control
- Maxicode Set Length 1
- PDF417
- PDF417 Set Length 1
- PDF417 Set Length 2
- Micro PDF417
- Micro PDF417 Length Control
- Micro PDF417 Set Length 2
- QR Code Enable / Disable
- qr code set length 1
- qr code set length 2
- Micro QR Code
- micro qr code set length 1
- micro qr code set length 2
- UCC Composite
- UCC Optional Composite Timer
- Postal Code Selection
- Postnet BB Control
- WIRELESS FEATURES
- WIRELESS BEEPER FEATURES
- Beep Duration
- Beep Volume
- Docking Beep
- CONFIGURATION UPDATES
- BATCH FEATURES
- Erase Batch Memory
- DIRECT RADIO AUTOLINK
- Bluetooth-Only Features
- Source Radio Address Delimiter Character
- BT SECURITY FEATURES
- Select PIN Code Length
- OTHER BT FEATURES
- Bluetooth HID Alt Mode
- HID Country Mode
- Power Off
- FEATURES FOR STAR MODELS ONLY
- STAR Radio Transmit Mode
- Motion Features
- Motion Sensitivity
- REFERENCES
- RS-232 Parameters
- RS-232/USB COM Parameters
- Keyboard Interface
- Intercode Delay
- Symbologies
- Data Editing
- Stand Mode Off Time
- Scanning Active Time
- Aiming Duration Time
- Flash Off Time
- RF Features
- BT-Only Features
- MESSAGE FORMATTING
- LED and Beeper Control
- TECHNICAL SPECIFICATIONS
- Imager Labeling
- Standard Cable Pinouts
- LED and Beeper Indications
- Error Codes
- Base Station Indications (Cordless Models ONLY)
- STANDARD DEFAULTS
- Table Of Contents
- Table Of Contents
- Table Of Contents
- QR Code Set Length 1
- SAMPLE BAR CODES
- d bar codes
- KEYPAD
- SCANCODE TABLES
- Interface Type PC AT PS/2, USB-Keyboard or USB-Keyboard for APPLE
- Interface type PC AT PS/2 Alt Mode or USB-Keyboard Alt Mode
- Digital Interface
- IBM31xx 102-key
- Microsoft Windows Codepage 1252
- ascii chart
Related products
Gryphon I GD4400Gryphon I GD4400-BGryphon I GD4430Gryphon I GD44XXGryphon I GM440XGryphon GD4400Gryphon I GDGryphon iGryphon i GD4110Gryphon I GD4100Datalogic categories
Barcode Reader
Accessories
Security Sensors
Scanner
Media Converter
Handhelds
Digital Camera
PDA
Safety Equipment
Security System
manualsdatabase
Your AI-powered manual search engine