Table of contents
- Table Of Contents
- Table Of Contents
- Preface
- Safety instructions
- Description
- Specifications
- Labels
- Preparing for installation
- Preparing the installation site
- Process purging
- Scope of supply and delivery
- Laying out tools and support materials
- Determining cable runs and line runs
- Installing components
- Installing insertion tubes
- Option: Installing the isolation flange
- Follow the safety information
- Installing the isolation flange
- Installing the purging flanges
- Roughly pre-aligning the purging flanges
- Connecting the purging lines
- Option: Installing the validation cell
- Installing the validation cell
- Installing the transmitter unit and receiver unit
- Connecting the electrical leads
- Observing cable specifications
- Protecting the line voltage supply
- Installing the junction box
- Fitting the cable clips and line brackets
- Selecting a suitable cable gland
- Leading cables through cable glands
- Establishing a protective grounding
- Connecting the transmitter unit to the junction box
- Connecting the receiver unit to the junction box
- Option: connecting the T/P probes to the junction box
- Connecting the analog and digital outputs to the junction box
- Connecting equipotential bonding
- Connecting the power supply
- Gas analyzer start-up
- Connecting the supply voltage
- Recognizing the operating status
- Connecting the PC to the junction box
- Connecting to the instrument software
- Menu structure of the instrument software
- Main menu
- System time menu
- Fine alignment of the purging flanges
- Alignment menu
- Installation procedure menu
- Installation - Cable length menu
- Installation - Process parameters menu
- Installation - Installation flanges menu
- Installation - Ambient conditions menu
- Installation - Channels menu
- Installation - Analog and digital outputs menu
- Installation - Save settings menu
- Maintaining and servicing the gas analyzer
- Monitoring optical transmission
- Checking and cleaning the components
- Testing the analyzer
- System information menu
- Instrument status menu
- Verification of I/O modules menu
- Diagnostics menu
- Service menu
- Network settings menu
- Spectrum menu
- Logging menu
- Validating and calibrating the gas analyzer
- Validation
- Validate using the internal validation cell
- Checking absorption lines in the spectrum
- Calibrating the gas analyzer
- Temporarily changing the configuration
- Calibration
- Calibration options menu
- Calibration settings menu
- Calibration menu
- Continuing measuring mode
- Recognizing and resolving errors
- Error messages in "Malfunction" status
- Gas analyzer shutdown
- Disassembling the gas analyzer
LS4000
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Preface
- Safety instructions
- Description
- General Purpose variant: Description
- Labels
- Scope of delivery
- ATEX variant: Description
- Safety rating
- Laser classification
- Labels for zone 1
- Labels for zone 2
- IECEx variant: Description
- KCs variant: Description
- CSA variant: Description
- Preparing for installation
- Preparing the system
- Preparing the installation site
- Process purging
- Laying out tools, installation materials and support materials
- Determining cable runs and line runs
- Installing components
- Installing insertion tubes
- Option: Installing the isolation flanges
- Follow the safety information
- Installing the isolation flanges
- Installing the purging flanges
- Roughly pre-aligning the purging flanges
- Connecting the purging lines
- Option: Installing the validation cell
- Installing the validation cell
- Installing the transmitter unit and receiver unit
- General Purpose variant: Electrical connections
- Observing cable specifications
- Protecting the line voltage supply
- Selecting a suitable cable gland
- Leading cables through cable glands
- Connecting the electrical leads
- Connecting the transmitter unit to the junction box
- Connecting the receiver unit to the junction box
- Option: Connecting the T/P probes to the junction box
- Connecting the analog and digital outputs to the junction box
- Connecting the potential equalization terminal
- Connecting the power supply
- ATEX variant: Electrical connections
- Installing the junction box
- Fitting the cable clips and line brackets
- IECEx variant: Electrical connections
- KCs variant: Electrical connections
- CSA variant: Electrical connections
- Gas analyzer start-up
- Connecting the supply voltage
- Connecting the PC to the junction box
- Connecting to the instrument software
- Menu structure of the instrument software
- Main menu
- System time menu
- Fine alignment of the purging flanges
- Alignment menu
- Installation procedure
- Installation – Process parameters menu
- Installation – Installation flanges menu
- Installation – Ambient conditions menu
- Installation – External inputs menu
- Installation – Channels menu
- Installation – Analog and digital outputs menu
- Installation – Network settings menu
- Installation – Save settings menu
- Maintaining and servicing the gas analyzer
- As required
- Annual
- System information menu
- Instrument status menu
- Verification of I/O modules menu
- Diagnostics menu
- Service menu
- Spectrum menu
- Logging menu
- Validating and calibrating the gas analyzer
- Validation
- Calibrating the gas analyzer
- Adjusting the configuration
- Calibration
- Calibration options menu
- Calibration settings menu
- Calibration menu
- Continuing measuring mode
- Recognizing and resolving errors
- Error messages in "Malfunction" status
- Shutting down the gas analyzer
- Disassembly