Daikin RXS35F2V1B manuals
RXS35F2V1B
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- List of Functions
- Part 2 Specifications
- Specifications
- Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Printed Circuit Board Connector Wiring Diagram
- Outdoor Unit
- Part 4 Function and Control
- Main Functions
- Wide Angle Louvers and Auto-Swing
- fan speed control
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- Night Set Mode
- Inverter POWERFUL Operation
- Other Functions
- WEEKLY TIMER
- Function of Thermistor
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Temperature Control
- Input Current Control
- Freeze-up Protection Control
- Fan Control
- Electronic Expansion Valve Control
- discharge pipe
- Malfunctions
- Forced Operation Mode
- Additional Function
- Facility Setting Switch (cooling at low outdoor temperature)
- Part 5 System Configuration
- System Configuration
- Instruction
- Names of Parts
- remote controller
- Preparation Before Operation
- AUTO • DRY • COOL • HEAT • FAN Operation
- Adjusting the Air Flow Direction
- air flow selection
- POWERFUL Operation
- OUTDOOR UNIT QUIET Operation
- ECONO Operation
- TIMER Operation
- WEEKLY TIMER Operation
- Care and Cleaning
- air filter
- before a long idle period
- Troubleshooting
- disposal requirements
- Part 6 Service Diagnosis
- Caution for Diagnosis
- Problem Symptoms and Measures
- Service Check Function
- Indoor Unit PCB Abnormality
- Freeze-up Protection Control or High Pressure Control
- Fan Motor (DC Motor) or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Signal Transmission Error (between Indoor and Outdoor Units)
- between indoor and outdoor units
- Outdoor Unit PCB Abnormality
- Compressor Lock
- DC Fan Lock
- Input Over Current Detection
- Four Way Valve Abnormality
- High Pressure Control in Cooling
- Compressor System Sensor Abnormality
- Position Sensor Abnormality
- DC Voltage / Current Sensor Abnormality
- CT or Related Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Over Current Detection
- Insufficient Gas
- Signal Transmission Error on Outdoor Unit PCB
- Check
- SiBE06
- thermistor resistance check
- installation condition check
- discharge pressure check
- power supply waveforms check
- capacitor voltage check
- main circuit electrolytic capacitor check
- Part 7 Removal Procedure
- Indoor Unit
- Removal of the Horizontal Blade
- Removal of the Electrical Box
- Removal of the PCB
- Removal of the Vertical Blade
- Removal of the Heat Exchanger
- Removal of the Fan Rotor / Fan Motor
- Outdoor Unit : 50 Class
- Removal of the Fan Motor / Propeller Fan
- Removal of the Sound Blanket
- Removal of the Four Way Valve
- Removal of the Compressor
- Part 8 Others
- Others
- Jumper Settings
- Part 9 Appendix
- Piping Diagrams
- Outdoor Units
- Wiring Diagrams