Panasonic S-22MF2E5A manuals
S-22MF2E5A
Table of contents
S-22MF2E5A
Table of contents
- operating instructions
- product information
- precautions for use
- names of parts
- tips for energy saving
- troubleshooting
- conditions de fonctionnement
- precauciones de seguridad
- condiciones de funcionamiento
- unidad interior
- precauzioni per la sicurezza
- risoluzione dei problemi
- unidade interior
- petunjuk keselamatan
- specifications
S-22MF2E5A
Table of contents
- special precautions
- Table Of Contents
- Section 1: CONTROL FUNCTIONS-Outdoor Unit
- Section 2: CONTROL FUNCTIONS-Indoor Unit
- Room Temperature Control
- Heating Standby
- Automatic Fan Speed Control
- Indoor Unit MOV Control
- Automatic Heating/Cooling Control
- Discharge Air Temperature Control
- Automatic Flap Control
- Electric Heater Control
- Ventilation Fan Output
- Parameter
- outdoor unit maintenance remote controller
- Section 5: REMOTE CONTROLLER FUNCTIONS
- Simple Settings Function
- Detailed Settings Function
- Remote Controller Servicing Functions
- test run function
- trouble diagnosis
- Section 7: TEST RUN from the remote controller (CZ-RTC3)
- Test Run
- Auto Address Setting
S-22MF2E5A
Table of contents
- indoor unit
- Table Of Contents
- Section 1: OUTLINE OF VRF SYSTEMS
- Section 2: DESIGN OF VRF SYSTEMS
- electrical wiring
- selecting the installation site
- Way Cassette 60×60
- Low Silhouette Ducted
- Ceiling
- Wall Mounted
- how to install the indoor unit
- optional parts
- Section 3: Control of VRF SYSTEMS
- Section 4: VRF SYSTEMS INDOOR UNIT SPECIFICATIONS
- Way Cassette Type (U1 Type)
- Low Silhouette Ducted Type (F2 Type)
- Way Cassette 60×60 Type (Y2 Type)
- Wall Mounted Type (K2 Type)
- Wall Mounted Type (K1 Type)
- Ceiling Type (T2 Type)
- fresh air intake
- Section 5: TEST RUN
- test run
- Auto Address Setting
- Section 6: ELECTRICAL DATA
- electrical data
- Section 7: PCB AND FUNCTIONS
- indoor unit control pcb switches and functions
- Section 8: CAPACITY TABLE
- Cooling Capacity of Indoor Unit
- Section 9: RENEWAL
S-22MF2E5A
Table of contents
- special precautions
- check of density limit
- precautions for installation using new refrigerant
- important information regarding the refrigerant used
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Introduction
- Compressor Control
- Output of PCB
- special control
- Outdoor Unit Fan Control
- Outdoor Unit CCU (command controller unit) Control
- Oil Control
- Way Valve Adjustment Control
- Defrost Control
- Demand Control
- Other Functions
- Detailed Settings in EEPROM of Outdoor Unit
- Outdoor Unit Control PCB
- Electrical Data
- Section 2: CONTROL FUNCTIONS - Indoor Unit
- Room Temperature Control
- Heating Standby
- Automatic Fan Speed Control
- Indoor Unit MOV Control
- Automatic Heating / Cooling Control
- Discharge Air Temperature Control
- Automatic Flap Control
- Fan Control during Dry Mode
- Ventilation Fan Output
- Parameter
- Section 3: OUTDOOR UNIT REPAIR PROCEDURES
- Removing Panels
- Discharging Compressor Oil
- Recovering Refrigerant
- Checking for Leakage After Repair
- Evacuating System
- Charging Compressor Oil
- Pumping Out Refrigerant from Outdoor Unit
- Compressor
- Section 4: OUTDOOR UNIT MAINTENANCE REMOTE CONTROLLER
- Overview
- Functions
- Ordinary Display Controls and Functions
- Monitoring Operations
- Outdoor Unit Alarm History Monitor
- Mode Settings
- Section 5: REMOTE CONTROLLER FUNCTIONS
- Simple Settings Function
- Detailed Settings Function
- Remote Controller Servicing Functions
- Section 6: TROUBLE DIAGNOSIS
- Contents of Remote Controller Switch Alarm Display
- Outdoor Unit Control Panel LED Display
- Mini VRF Alarm Codes
- Inspection and Characteristics of Parts
- Test Pin
- Section 7: TEST RUN
- Preparing for Test Run
- Test Run Procedure
- Main Outdoor Unit P.C.Board Setting
- Auto Address Setting
- Setting Test Run Remote Controller
- Caution for Pump Down