Daikin Super Multi NX FCQ50C8VEB manuals
Super Multi NX FCQ50C8VEB
Table of contents
- technical data
- Table Of Contents
- Technical Specifications
- Electrical Specifications (50Hz)
- Safety device settings
- 4 Options
- Dimensional drawing & centre of gravity
- Dimensional drawing for auto cleaning panel
- Dimensional drawing with accessories
- Centre of gravity
- 6 Piping diagram
- Wiring diagram
- Sound data
- sound pressure spectrum
- Sound power spectrum
Super Multi NX FCQ50C8VEB
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- Functions
- Cooling Only - Outdoor Unit
- Heat Pump - Indoor Unit
- Heat Pump - Outdoor Unit
- Part 2 Specifications
- Specifications
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Indoor Unit
- Floor Standing Type
- Floor / Ceiling Suspended Dual Type
- Duct Connected Type
- Ceiling Mounted Cassette Type
- Ceiling Mounted Built-in Type
- Ceiling Suspended Type
- Remote Controller
- Wireless Remote Controller
- Outdoor Unit
- Part 4 Function and Control
- Function of Indoor Unit (RA Models)
- Operation Starting Control
- Airflow Direction Control
- Fan Speed Control for Indoor Units
- Program Dry Operation
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- ECONO Operation
- HOME LEAVE Operation
- Area INTELLIGENT EYE Operation
- INTELLIGENT EYE Operation
- Inverter POWERFUL Operation
- Other Functions
- Function of Indoor Unit (SA Models)
- Thermostat Sensor in Remote Controller
- Freeze Prevention Control
- Hot Start Control (In Heating Operation Only)
- Function of Thermistor
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Temperature Control
- Input Current Control
- Heating Peak-cut Control
- Liquid Compression Protection Function
- Low Hz High Pressure Limit
- pressure equalizing control
- Malfunctions
- Part 5 Operation Manual
- System Configuration
- RA Indoor Unit
- name of parts
- fan operation
- operating conditions
- FTXS, FVXS Series - ARC452A1, A3
- names of parts
- opening the front panel
- ATXS, FLK(X)S, FDK(X)S Series - ARC433B67, B68, B69, B76
- SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
- BRC1E51A7
- operation mode
- program dry
- key lock
- airflow direction
- ventilation mode
- schedule timer
- holiday setting
- convenient functions
- clock setting
- useful information
- BRC7E530W/531W, BRC7F532F/533F, BRC7EA63W/66
- operation range
- operation procedure
- Part 6 Service Diagnosis
- Troubleshooting with LED
- Problem Symptoms and Measures
- Service Check Function
- Code Indication on Remote Controller
- Troubleshooting for RA Indoor Unit - F(C)TXG FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
- Freeze-up Protection Control or Heating Peak-cut Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault (FTXG and CTXG Series)
- Signal Transmission Error (between Indoor Unit and Outdoor Unit)
- Unspecified Voltage (between Indoor Unit and Outdoor Unit)
- Troubleshooting for SA Indoor Unit - FFQ, FCQ FDBQ, FBQ, FHQ Series
- Drain Water Level System Abnormality
- Swing Motor Lock (FHQ Series)
- Drain System Abnormality
- Thermistor or Related Abnormality
- Remote Controller Thermistor Abnormality
- Field Setting Abnormality
- Troubleshooting for Outdoor Unit
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- dc fan lock
- Input Overcurrent Detection
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- CT or Related Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Overcurrent Detection
- Refrigerant Shortage
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (on Outdoor Unit PCB)
- Check
- Fan Motor Connector Check
- Electronic Expansion Valve Check
- Four Way Valve Performance Check
- Inverter Checker" Check
- Rotation Pulse Check on the Outdoor Unit PCB
- Installation Condition Check
- Outdoor Fan System Check
- Part 7 Removal Procedure
- Outdoor Unit - 50~75 Class
- Removal of Electrical Box
- Removal of PCBs
- Removal of Outdoor Fan / Fan Motor
- Removal of Sound Blankets
- Removal of Coils / Thermistors
- Removal of Distributor
- Removal of Four Way Valve
- Removal of Compressor
- Outdoor Unit - 80/90 Class
- Removal of Fan Motor
- Part 8 Trial Operation and Field Settings
- Pump Down Operation
- Forced Operation
- Wiring Error Check Function
- Trial Operation
- Field Settings
- jumper and switch settings
- Application of Silicon Grease to a Power Transistor and a Diode Bridge
- Part 9 Appendix
- Piping Diagrams
- Wiring Diagrams