Daikin Super Multi NX FHQ60BVV1B manuals
Super Multi NX FHQ60BVV1B
Table of contents
- Part 1 List of Functions ................................................................ 1
- part 1 list of functions
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- List of Functions
- list of functions
- heat pump
- Specifications
- specifications
- indoor units
- duct connected type
- ceiling mounted cassette type
- ceiling suspended type
- outdoor units
- floor standing type
- Printed Circuit Board Connector Wiring Diagram
- outdoor unit
- wall mounted type 20/25/35 class
- wall mounted type 50/60/71 class
- ceiling mounted cassette 600×600 type
- Refrigerant Circuit
- refrigerant circuit
- functional parts layout
- Refrigerant Flow for Each Operation Mode
- Heating Operation
- Cooling Oil Return Operation
- heating oil return operation & defrost operation
- Part 5 Function
- Part 5 Function
- Normal Operation
- Compressor PI Control
- compressor pi control
- Electronic Expansion Valve PI Control
- Cooling Operation Fan Control
- Special Control
- Oil Return Operation
- Defrosting Operation
- Pump-down Residual Operation
- Stopping Operation
- Protection Control
- Low Pressure Protection Control
- Discharge Pipe Protection Control
- Inverter Protection Control
- Freeze-up Protection Control
- Dew Condensation Prevention Control
- Other Control
- BP Unit Control
- BP Unit Electronic Expansion Valve Control
- full closing of electronic expansion valves
- SH Control in Cooling Operation
- SC Control in Heating Operation
- Indoor Unit (RA Models)
- Fan Speed Control for Indoor Units
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- Night Set Mode
- ECONO Mode
- INTELLIGENT EYE (Wall Mounted Type Only)
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Other Functions
- Indoor Unit (SkyAir Models)
- Electric Function Parts
- Function Details
- drain pump control
- Test Operation
- test operation
- check operation
- outdoor unit pcb layout
- field setting from outdoor unit
- detail of setting mode
- setting of low noise operation and demand operation
- setting of refrigerant additional charging operation
- Field Setting
- wired remote control
- Initial Setting Contents
- Local Setting Mode Number
- Detailed Explanation of Setting Modes
- Centralized Group No. Setting
- Maintenance Mode Setting
- Test Operation and Field Setting for RA Indoor Unit
- Jumper Settings
- System Configuration
- Instruction
- Wall Mounted, Duct, Floor/Ceiling, Floor Standing Type
- safety precautions
- installation site
- names of parts
- remote control
- indoor unit
- preparation before operation
- to set the clock
- auto dry cool heat fan operation
- to change the air flow rate setting
- adjusting the air flow direction
- air flow selection
- powerful operation
- outdoor unit silent operation
- econo operation
- mold proof operation
- intelligent eye operation
- timer operation
- to use on timer operation
- note for multi system
- priority room setting
- care and cleaning
- air filter
- before a long idle period
- front panel
- front grille
- cleaning the air filter
- troubleshooting
- check again
- Ceiling Mounted Cassette Type
- temperature setting
- Ceiling Mounted Built-in Type
- Ceiling Suspended Type
- operation range
- Part 8 Troubleshooting
- Table Of Contents
- Table Of Contents
- Caution for Diagnosis
- Troubleshooting with the LED on the SkyAir Indoor Unit
- Troubleshooting with the LED on the Outdoor Unit
- Troubleshooting with the LED on the BP Unit
- Service Check Function
- SkyAir Indoor Unit INSPECTION/TEST Button
- SkyAir Indoor Unit Wired Remote Control
- SkyAir Indoor Unit Infrared Remote Control
- Sky Air Indoor Unit Error Codes and LED Indication
- Malfunction Code Indication by Outdoor Unit PCB
- List of Malfunction Code
- Troubleshooting for RA Indoor Unit
- Freeze-up Protection Control or High Pressure Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Shutter Drive Motor / Shutter Limit Switch Abnormality
- Check
- thermistor resistance check
- hall ic check
- Troubleshooting for SkyAir Indoor Unit
- Malfunction of Drain Water Level System (Float Type)
- Malfunction of Drain System
- Indoor Unit Fan Motor Lock
- Malfunction of Indoor Unit Fan Motor
- Swing Flap Motor Malfunction / Lock
- Malfunction of Capacity Setting
- Malfunction of Heat Exchanger Thermistor (R2T)
- Malfunction of Heat Exchanger Thermistor (R3T)
- Malfunction of Suction Air Thermistor
- Malfunction of Remote Control Thermistor
- Transmission Error (between Indoor Unit and Remote Control)
- Transmission Error (between Main and Sub Remote Control)
- Malfunction of Field Setting Switch
- Troubleshooting for BP Unit
- Faulty BP Unit PCB
- Faulty BP Liquid or Gas Pipe Thermistor
- Transmission Error between Indoor Unit and BP Unit
- Transmission Error between Outdoor Unit and BP Unit
- Troubleshooting for Outdoor Unit
- Actuation of High Pressure Switch
- Actuation of Low Pressure Sensor
- Compressor Motor Lock
- Malfunction of Outdoor Unit Fan Motor
- Abnormal Discharge Pipe Temperature
- Refrigerant Overcharged
- Malfunction of Thermistor for Outdoor Air (R1T)
- Malfunction of Discharge Pipe Thermistor (R2T)
- Malfunction of Thermistor (R3T, R5T) for Suction Pipe1, 2
- Malfunction of Thermistor (R4T) for Outdoor Unit Heat Exchanger
- Malfunction of Thermistor (R7T) for Outdoor Unit Liquid Pipe
- Malfunction of Subcooling Heat Exchanger Thermistor (R6T)
- Malfunction of High Pressure Sensor
- Malfunction of Low Pressure Sensor
- Malfunction of PCB
- Malfunction of Inverter Radiating Fin Temperature Rise
- Inverter Compressor Abnormal
- Inverter Current Abnormal
- Inverter Start up Error
- Malfunction of Transmission between Inverter and Control PCB
- High Voltage of Capacitor in Main Inverter Circuit
- Malfunction of Inverter Radiating Fin Temperature Rise Sensor
- Faulty Combination of Inverter and Fan Driver
- Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
- Power Supply Insufficient or Instantaneous Failure
- Check Operation not Executed
- Malfunction of Transmission between Indoor Units and Outdoor Units
- Malfunction of Transmission between Remote Control and Indoor Unit
- Malfunction of Transmission between Main and Sub Remote Controls
- Outdoor Units in the Same System
- Excessive Number of Indoor Units
- Address Duplication of Central Remote Control
- Malfunction of Transmission between Central Remote Control and Indoor Unit
- System is not Set yet
- Malfunction of System, Refrigerant System Address Undefined
- Thermistor Resistance / Temperature Characteristics
- Pressure Sensor
- Method of Replacing The Inverter's Power Transistors Modules
- Part 9 Appendix
- Piping Diagrams
- BP Units
- Indoor Units
- Wiring Diagrams
- Table Of Contents
- Table Of Contents
- Table Of Contents
Super Multi NX FHQ60BVV1B
Table of contents
- Part 1 List of Functions ................................................................ 1
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- cautions regarding products after repair
- inspection after repair
- using icons
- Part 1 List of Functions
- List of Functions
- Specifications
- Indoor Units
- duct connected type
- floor standing type
- ceiling mounted cassette type
- printed circuit board
- Printed Circuit Board Connector Wiring Diagram
- Branch Provider Unit
- Wall Mounted Type 20/25/35/50 Class - D Series
- Wall Mounted Type 20/25/35 Class - C Series
- Wall Mounted Type 50/60/71 Class - E(B) Series
- Duct Connected Type
- Floor / Ceiling Suspended Dual Type
- Floor Standing Type
- ceiling mounted cassette 600×600 type
- Ceiling Suspended Type
- Refrigerant Circuit
- BP Units
- Functional Parts Layout
- Refrigerant Flow for Each Operation Mode
- Heating Operation
- Cooling Oil Return Operation
- heating oil return operation & defrost operation
- Function
- Part 5 Function
- Operation Mode
- Basic Control
- Compressor PI Control
- Electronic Expansion Valve PI Control
- Cooling Operation Fan Control
- Special Control
- Oil Return Operation
- Defrosting Operation
- Pump-down Residual Operation
- Stopping Operation
- Protection Control
- Low Pressure Protection Control
- Discharge Pipe Protection Control
- Inverter Protection Control
- Freeze-up Protection Control
- Dew Condensation Prevention Control
- Other Control
- BP Unit Control
- BP Unit Electronic Expansion Valve Control
- full closing of electronic expansion valves
- SH Control in Cooling Operation
- SC Control in Heating Operation
- Indoor Unit (RA Models)
- Fan Speed Control for Indoor Units
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- Night Set Mode
- ECONO Mode
- INTELLIGENT EYE
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Other Functions
- Indoor Unit (SkyAir Models)
- Electric Function Parts
- Function Details
- Test Operation
- check operation
- Outdoor Unit PCB Layout
- Field Setting
- Detail of Setting Mode
- Field Setting for SkyAir Indoor Unit
- Initial Setting Contents
- Local Setting Mode Number
- Detailed Explanation of Setting Modes
- Centralized Group No. Setting
- Maintenance Mode Setting
- Test Operation and Field Setting for RA Indoor Unit
- Jumper Settings
- System Configuration
- Instruction
- Wall Mounted, Duct, Floor/Ceiling, Floor Standing Type
- safety precautions
- installation site
- names of parts
- Table Of Contents
- indoor unit
- outdoor unit
- remote control
- " Outdoor Unit
- Table Of Contents
- to set the clock
- to change the air flow rate setting
- adjusting the air flow direction
- air flow selection
- powerful operation
- outdoor unit silent operation
- econo operation
- intelligent eye operation
- timer operation
- to use on timer operation
- note for multi system
- priority room setting
- care and cleaning
- air filter
- before a long idle period
- front panel
- cleaning the air filter
- front grille
- troubleshooting
- Ceiling Mounted Cassette Type
- temperature setting
- operation range
- air flow direction adjust
- Troubleshooting
- Table Of Contents
- Table Of Contents
- Caution for Diagnosis
- Troubleshooting with the LED on the SkyAir Indoor Unit
- Troubleshooting with the LED on the Outdoor Unit
- Troubleshooting with the LED on the BP Unit
- Service Check Function
- SkyAir Indoor Unit INSPECTION/TEST Button
- SkyAir Indoor Unit Wired Remote control
- SkyAir Indoor Unit Infrared remote control
- service check function
- Sky Air Indoor Unit Error Codes and LED Indication
- Malfunction Code Indication by Outdoor Unit PCB
- List of Malfunction Code
- Troubleshooting for RA Indoor Unit
- Freeze-up Protection Control or High Pressure Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Shutter Drive Motor / Shutter Limit Switch Abnormality
- Check
- thermistor resistance check
- hall ic check
- Troubleshooting for SkyAir Indoor Unit
- Malfunction of Drain Water Level System (Float Type)
- Malfunction of Drain System
- Indoor Unit Fan Motor Lock
- Malfunction of Indoor Unit Fan Motor
- Swing Flap Motor Malfunction / Lock
- Malfunction of Capacity Setting
- Malfunction of Heat Exchanger Thermistor (R2T)
- Malfunction of Heat Exchanger Thermistor (R3T)
- Malfunction of Suction Air Thermistor
- Malfunction of Remote control Thermistor
- Transmission Error (between Indoor Unit and Remote control)
- Transmission Error (between Main and Sub Remote control)
- Malfunction of Field Setting Switch
- Troubleshooting for BP Unit
- Faulty BP Unit PCB
- Faulty BP Liquid or Gas Pipe Thermistor
- Transmission Error between Indoor Unit and BP Unit
- Transmission Error between Outdoor Unit and BP Unit
- Troubleshooting for Outdoor Unit
- Actuation of High Pressure Switch
- Actuation of Low Pressure Sensor
- Compressor Motor Lock
- Malfunction of Outdoor Unit Fan Motor
- Abnormal Discharge Pipe Temperature
- Refrigerant Overcharged
- Malfunction of Thermistor for Outdoor Air (R1T)
- Malfunction of Discharge Pipe Thermistor (R2T)
- Malfunction of Thermistor (R3T, R5T) for Suction Pipe1, 2
- Malfunction of Thermistor (R4T) for Outdoor Unit Heat Exchanger
- Malfunction of Thermistor (R7T) for Outdoor Unit Liquid Pipe
- Malfunction of Subcooling Heat Exchanger Thermistor (R6T)
- Malfunction of High Pressure Sensor
- Malfunction of Low Pressure Sensor
- Malfunction of PCB
- Malfunction of Inverter Radiating Fin Temperature Rise
- Inverter Compressor Abnormal
- Inverter Current Abnormal
- Inverter Start up Error
- Malfunction of Transmission between Inverter and Control PCB
- High Voltage of Capacitor in Main Inverter Circuit
- Malfunction of Inverter Radiating Fin Temperature Rise Sensor
- Faulty Combination of Inverter and Fan Driver
- Low Pressure Drop Due to Refrigerant Shortage or Electronic Expansion Valve Failure
- Power Supply Insufficient or Instantaneous Failure
- Check Operation not Executed
- Malfunction of Transmission between Indoor Units and Outdoor Units
- Malfunction of Transmission between Remote control and Indoor Unit
- Malfunction of Transmission between Main and Sub Remote controls
- Malfunction of Transmission between Indoor and Outdoor Units in the Same System
- Excessive Number of Indoor Units
- Address Duplication of Central Remote control
- malfunction of transmission between central remote
- System is not Set yet
- Malfunction of System, Refrigerant System Address Undefined
- Thermistor Resistance / Temperature Characteristics
- Pressure Sensor
- Method of Replacing The Inverter's Power Transistors Modules
- Part 9 Appendix
- Piping Diagrams
- Wiring Diagrams
- Table Of Contents
- Table Of Contents
Super Multi NX FHQ60BVV1B
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- List of Functions
- Heat Pump Models
- Part 2 Specifications
- Specifications
- Outdoor Units - Cooling Only
- Indoor Units - Heat Pump
- Outdoor Units - Heat Pump
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Printed Circuit Board Connector Wiring Diagram
- Duct Connected Type
- Floor / Ceiling Suspended Dual Type
- Floor Standing Type
- Ceiling Suspended Type
- Outdoor Units
- Part 4 Function and Control
- Main Functions
- Power-Airflow Dual Flaps, Wide Angle Louvers and Auto-Swing
- Operation Starting Control
- Fan Speed Control for Indoor Units
- Programme Dry Function
- Automatic Operation
- Thermostat Control
- Night Set Mode
- ECONO Mode
- INTELLIGENT EYE (Wall Mounted Type only)
- HOME LEAVE Operation
- Inverter POWERFUL Operation
- Other Functions
- Function of Main Structural Parts
- Function of Thermistor
- cooling only model
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- compressor protection function
- Discharge Pipe Control
- Freeze-up Protection Control
- Fan Control
- Defrost Control
- Electronic Expansion Valve Control
- Malfunctions
- Forced Operation Mode
- Wiring-Error Check
- Additional Function
- Part 5 Operation Manual
- System Configuration
- Instruction
- safety precautions
- FVXS Series
- air flow selection
- FHQ Series
- temperature setting
- Part 6 Service Diagnosis
- Caution for Diagnosis
- Problem Symptoms and Measures
- Service Check Function
- Check Method 2
- Code Indication on the Remote Control
- Troubleshooting
- Indoor Unit PCB Abnormality
- Freeze-up Protection Control or High Pressure Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault
- Signal Transmission Error (between Indoor and Outdoor Unit)
- Unspecified Voltage (between Indoor and Outdoor Units)
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- DC Fan Lock
- Input Over Current Detection
- Discharge Pipe Temperature Control
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- CT or Related Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- SiENBE12
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Over Current Detection
- Insufficient Gas
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (on Outdoor Unit PCB)
- Check
- electronic expansion valve check
- four way valve performance check
- installation condition check
- discharge pressure check
- power supply waveforms check
- capacitor voltage check
- main circuit electrolytic capacitor check
- hall ic check
- Part 7 Removal Procedure
- Outdoor Unit
- Removal of the Electrical Box
- Removal of the PCB
- Removal of the Propeller Fan / Fan Motor
- Removal of the Sound Blanket
- Removal of Electronic Expansion Valve Coil Four Way Valve Coil and Thermistor
- Removal of the Distributor
- Removal of the Four Way Valve
- Removal of the Compressor
- Part 8 Others
- Others
- Jumper Settings
- Part 9 Appendix
- Piping Diagrams
- Wiring Diagrams
Super Multi NX FHQ60BVV1B
Table of contents
Super Multi NX FHQ60BVV1B
Table of contents
Super Multi NX FHQ60BVV1B
Table of contents
Super Multi NX FHQ60BVV1B
Table of contents
Super Multi NX FHQ60BVV1B
Table of contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Table Of Contents
- safety cautions
- Part 1 List of Functions
- Functions
- Cooling Only - Outdoor Unit
- Heat Pump - Indoor Unit
- Heat Pump - Outdoor Unit
- Part 2 Specifications
- Specifications
- Part 3 Printed Circuit Board Connector Wiring Diagram
- Indoor Unit
- Floor Standing Type
- Floor / Ceiling Suspended Dual Type
- Duct Connected Type
- Ceiling Mounted Cassette Type
- Ceiling Mounted Built-in Type
- Ceiling Suspended Type
- Remote Controller
- Wireless Remote Controller
- Outdoor Unit
- Part 4 Function and Control
- Function of Indoor Unit (RA Models)
- Operation Starting Control
- Airflow Direction Control
- Fan Speed Control for Indoor Units
- Program Dry Operation
- Automatic Operation
- Thermostat Control
- NIGHT SET Mode
- ECONO Operation
- HOME LEAVE Operation
- Area INTELLIGENT EYE Operation
- INTELLIGENT EYE Operation
- Inverter POWERFUL Operation
- Other Functions
- Function of Indoor Unit (SA Models)
- Thermostat Sensor in Remote Controller
- Freeze Prevention Control
- Hot Start Control (In Heating Operation Only)
- Function of Thermistor
- Control Specification
- Frequency Control
- Controls at Mode Changing / Start-up
- Discharge Pipe Temperature Control
- Input Current Control
- Heating Peak-cut Control
- Liquid Compression Protection Function
- Low Hz High Pressure Limit
- pressure equalizing control
- Malfunctions
- Part 5 Operation Manual
- System Configuration
- RA Indoor Unit
- name of parts
- fan operation
- operating conditions
- FTXS, FVXS Series - ARC452A1, A3
- names of parts
- opening the front panel
- ATXS, FLK(X)S, FDK(X)S Series - ARC433B67, B68, B69, B76
- SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series
- BRC1E51A7
- operation mode
- program dry
- key lock
- airflow direction
- ventilation mode
- schedule timer
- holiday setting
- convenient functions
- clock setting
- useful information
- BRC7E530W/531W, BRC7F532F/533F, BRC7EA63W/66
- operation range
- operation procedure
- Part 6 Service Diagnosis
- Troubleshooting with LED
- Problem Symptoms and Measures
- Service Check Function
- Code Indication on Remote Controller
- Troubleshooting for RA Indoor Unit - F(C)TXG FTXS, ATXS, FVXS, FLK(X)S, FDK(X)S Series
- Freeze-up Protection Control or Heating Peak-cut Control
- Fan Motor or Related Abnormality
- Thermistor or Related Abnormality (Indoor Unit)
- Front Panel Open / Close Fault (FTXG and CTXG Series)
- Signal Transmission Error (between Indoor Unit and Outdoor Unit)
- Unspecified Voltage (between Indoor Unit and Outdoor Unit)
- Troubleshooting for SA Indoor Unit - FFQ, FCQ FDBQ, FBQ, FHQ Series
- Drain Water Level System Abnormality
- Swing Motor Lock (FHQ Series)
- Drain System Abnormality
- Thermistor or Related Abnormality
- Remote Controller Thermistor Abnormality
- Field Setting Abnormality
- Troubleshooting for Outdoor Unit
- Outdoor Unit PCB Abnormality
- OL Activation (Compressor Overload)
- Compressor Lock
- dc fan lock
- Input Overcurrent Detection
- High Pressure Control in Cooling
- Compressor Sensor System Abnormality
- Position Sensor Abnormality
- CT or Related Abnormality
- Thermistor or Related Abnormality (Outdoor Unit)
- Electrical Box Temperature Rise
- Radiation Fin Temperature Rise
- Output Overcurrent Detection
- Refrigerant Shortage
- Low-voltage Detection or Over-voltage Detection
- Signal Transmission Error (on Outdoor Unit PCB)
- Check
- Fan Motor Connector Check
- Electronic Expansion Valve Check
- Four Way Valve Performance Check
- Inverter Checker" Check
- Rotation Pulse Check on the Outdoor Unit PCB
- Installation Condition Check
- Outdoor Fan System Check
- Part 7 Removal Procedure
- Outdoor Unit - 50~75 Class
- Removal of Electrical Box
- Removal of PCBs
- Removal of Outdoor Fan / Fan Motor
- Removal of Sound Blankets
- Removal of Coils / Thermistors
- Removal of Distributor
- Removal of Four Way Valve
- Removal of Compressor
- Outdoor Unit - 80/90 Class
- Removal of Fan Motor
- Part 8 Trial Operation and Field Settings
- Pump Down Operation
- Forced Operation
- Wiring Error Check Function
- Trial Operation
- Field Settings
- jumper and switch settings
- Application of Silicon Grease to a Power Transistor and a Diode Bridge
- Part 9 Appendix
- Piping Diagrams
- Wiring Diagrams