1-43If the RUN LED flashes at a high frequency, the card is in the startup process, but is not yet operational.At system startup, the ALM LED will be ON for a while, but it does not mean that the card is faulty.z ACTIVE LEDThe ACTIVE LED shows the active/standby status of the LSQ1SRPB0. If the ACTIVE LED is ON, theLSQ1SRPB0 is active; if OFF, the LSQ1SRPB0 is standby.RESET buttonA reset button is provided on the LSQ1SRPB0 for you to reset the card when necessary.Salience VI-Turbo SRPU-LSQ1SRP1CB0Applicable modelsz S7503Ez S7506Ez S7510Ez S7506E-VTechnical specificationsTable 1-70 Technical specifications of LSQ1SRP1CB0Item SpecificationsCPU MIPS64, 600 MHzBoot ROM 512 KBFlash memory 64 MBDDR SDRAM 512 MBDimensions (H × W × D) 45 × 377 × 355 mm (1.77 × 14.84 × 13.98 in.)Interfacesz One CF card slotz One console port, used for local or remote configuration andmanagement of the switch through a dialup connectionz One 10/100Base-TX management portPower consumption 53 W to 60 WPanel and LEDsFigure 1-26 shows the front panel of the LSQ1SRP1CB0.