ABB ACS150 Quick Installation And Start-up Manual
Also see for ACS150 series: User manualUser manualUser manualUser manualInstallation instructions
Safety instructionsWARNING! Obey these instructions. If you ignore them, injury or death,or damage to the equipment can occur. If you are not a qualifiedelectrical professional, do not do electrical installation or maintenancework.• Keep the drive in its package until you install it. After unpacking, protect thedrive from dust, debris and moisture.• Use the required personal protective equipment: safety shoes with metal toecap, safety glasses, protective gloves and long sleeves, etc.• When the drive or connected equipment is energized, do not do work on thedrive, motor cable, motor, control cables or control circuits. Electrical safety precautions1. Clearly identify the work location and equipment.2. Disconnect all possible voltage sources. Make sure that re-connection is notpossible. Lock out and tag out.• Open the main disconnecting device of the drive.• Disconnect any dangerous external voltages from the control circuits.• After you disconnect power from the drive, always wait 5 minutes to letthe intermediate circuit capacitors discharge before you continue.3. Protect any other energized parts in the work location against contact.4. Take special precautions when close to bare conductors.5. Measure that the installation is de-energized.• Use a multimeter with a minimum impedance of 1 Mohm.• Make sure that the voltage between the drive input power terminals (U1,V1, W1) and the ground (PE) is close to 0 V.• Make sure that the voltage between the drive output terminals (U2, V2,W2) and the ground (PE) is close to 0 V.• Make sure that the voltage between the drive DC terminals (BRK+ andBRK-) and the ground (PE) is close to 0 V.6. Install temporary grounding as required by the local regulations.7. Ask the person in control of the electrical installation work for a permit towork.See the drive user’s manual for the complete safety instructions.1. Examine the installation areaThe drive is intended for cabinet installation and has a degree of protection ofIP20 / UL open type as standard.Make sure that in the installation area:• There is sufficient space above and below the drive for cooling, and hot airdoes not recirculate. Refer toFree space requirements.• The ambient conditions are suitable. Refer toAmbient conditions.• The mounting surface is non-flammable and can hold the weight of the drive.Refer toDimensions and weights.• Materials near the drive are non-flammable.• There are no sources of strong magnetic fields, such as high-current single-core conductors or contactor coils near the drive. A strong magnetic fieldcan cause interference in the operation of the drive.2. Install the driveYou can install the drive with screws or to a DIN rail [Top Hat, W x H = 35 ×7.5 mm (1.4 × 0.3 in)].• Make sure that there is a minimum of 75 mm (3 in) of free space above andbelow the drive for cooling air.• When placing drives on top of each other in a panel or cabinet, make surethat the hot air from the drives below do not directly enter the drive above.WARNING! Do not install the drive upside down. Make sure that thecooling air exhaust (at the top) is above the cooling air inlet (at thebottom). To install the drive with screws1. Cut out the mountingtemplate from thepackage and use it tomark the locations forthe mounting holes.2. Make the holes for themounting screws andinstall suitable plugs oranchors.—ABB MIRCO DRIVESACS150 drivesQuick installation and start-up guide3. Start to tighten thescrews into themounting holes.4. Place the drive ontothe mounting screws.5. Tighten the mountingscrews securely. To install thedrive to a DINrail1. Place the top of thedrive onto the DINinstallation rail in anangle as shown infigure.2. Set the drive againstthe wall.3. To remove the drive,press the release leveron top of the drive.3. Attach the clamping plates1. Fasten the clampingplate to the plate atthe bottom of thedrive with theprovided screws.2. Fasten the I/Oclamping plate to theclamping plate withthe provided screws.4. Measure theinsulation resistanceMeasuring the insulation is typically not required in North America.Drive: Do not do voltage tolerance or insulation resistance tests on the drive,because this can cause damage to the drive.Input power cable: Before you connect the input power cable, measure theinsulation of the input power cable. Obey the local regulations.Motor and motor cable:1. Make sure that the motor cable is connected to the motor and disconnectedfrom the drive output terminals U2, V2 and W2.2. Use a voltage of 1000 V DC to measure theinsulation resistance between each phaseconductor and the protective earth conductor.The insulation resistance of an ABB motor mustbe more than 100 Mohm (at 25 °C/77 °F). For theinsulation resistance of other motors, refer tothe manufacturer’s documentation. Moisture inthe motor decreases the insulation resistance.If you think that there is moisture in the motor,dry the motor and do the measurement again.5. Select the cablesInput power cable: IEC/EN 61800-5-1 requires two protective earth (ground)conductors. Prefer a symmetrical shielded cable (VFD cable).Motor cable: Use a symmetrical shielded cable (VFD cable) for the best EMCperformance and to meet the European EMC requirements.Control cable: Use a double-shielded twisted-pair cable for analog signals. Use adouble- or single-shielded cable for digital, relay and I/O signals. Do not mix 24 Vand 115/230 V signals in the same cable.6. Connect the power cables Connection diagram (shielded cables) Connection procedure (shielded cables)WARNING! Make sure that the drive is compatible with the earthingsystem. You can connect all drive types to a symmetrically groundedTN-S system. For other systems, see the drive user’s manual.1. Strip the inputpower cable. Groundthe cable shield (ifany) under thegrounding clamp.Twist the cableshield into a bundle,mark it accordinglyand connect it to thegrounding terminal.Connect othergroundingconductors (PE) to the grounding terminal. Connect the phase conductors tothe U1, V1 and W1 terminals.2. Strip the motor cable. Ground the cable shieldunder the grounding clamp. Twist the motorcable shield into a bundle, mark it accordinglyand connect it to the grounding terminal.Connect the phase conductors to the U2, V2 andW2 terminals.3. If applicable, connect the brake resistor cable tothe BRK+ and BRK- terminals. Use a shieldedcable and ground the shield under thegrounding clamp.4. Mechanically attach the cables on the outside ofthe drive.1 360-degree grounding of the cable shield. Required for the motor cable and brakeresistor cable, recommended for the input power cable.2 Use a separate grounding cable if the conductivity of the cable shield is not sufficient(smaller than the conductivity of the phase conductor) for the protective grounding, orthere is no symmetrically constructed grounding conductor in the cable.3 In one-phase installations, connect phase to U1/L, neutral to V1/N and leave W1disconnected.4 Use two grounding conductors if the cross-section of a single grounding conductor isless than 10 mm2 Cu or 16 mm2 AI (IEC/EN 61800-5-1). For example, use the cable shieldin addition to the fourth conductor.5 Use a separate grounding cable (line side) if the conductivity of the fourth conductor orshield is not sufficient for the protective grounding.1000 V DC 100 M hM3~U1V1W1 PEohmU2 V2 W21)DriveU1/L V1/N W1Motor3 ~V1U1 W1PEPE L1/L L2/N L3/-2)BRK+ BRK-Optional brakeresistor3)5)1)4)7. Connect the control cables Default I/O connectionsThe diagram shows the I/O connections when parameter9902 has value 1(ABB STANDARD). Connection procedureTo prevent inductive coupling, keep the signal wire pairs twisted all the way upto the terminals.5. Strip the outer insulation of thecable and ground the bare shield360 degrees under the clamp.6. Connect the conductors to thecorrect control terminals. Torquethe input signals to 0.22 N·m(2 lbf·in) and relay output to 0.5 N·m(4.4 lbf·in).7. For double-shielded cables, twistalso the grounding conductors ofeach pair in the cable together andconnect the bundle to the SCR terminal (terminal 1).8. Mechanically attach the control cables on the outside of the drive.8. Start up the driveWARNING! Before you start up the drive, make sure that the installationis complete. Make sure that the cover of the drive is in place. Make surealso that the motor does not cause danger when it starts. Disconnectthe motor from other machinery, if there is a risk of damage or injury.There is an extensive installation checklist in the drive user’s manual.Before you start, ensure that you have the motor nameplate data at hand.Frame size Tightening torquesU1, V1, W1, U2, V2, W2,BRK+ and BRK-PER0…R2 0.8 N·m (7 lbf·in) 1.2 N·m (11 lbf·in)00353783 LI/O connection 4)SCR Signal cable shield (screen)AI Frequency reference: 0…20 mAGND Analog input circuit common+10V Reference voltage: +10 V DC, max. 10 mA+24V Auxiliary voltage output: +24 V DC, max. 200 mAGND Auxiliary voltage output commonCOM Digital input commonDI1 Stop (0) / Start (1)DI2 Forward (0) / Reverse (1)DI3 Constant speed selection 1)DI4 Constant speed selection 1)DI5 Acceleration and deceleration selection 2)Relay connection 5)COM Relay outputNo fault [Fault (-1)]NCNOAlternative connection for AI1:SCR If you use voltage signal instead or current, switch the IUselector to U (0…10 V voltage signal), and use thisconnection instead the one shown above.AIGND+10V1) See parameter group 12 CONSTANTSPEEDS:2) 0 = ramp times according to parameters2202 and2203. 1 = ramp times according toparameters2205 and2206.3) 360 degree grounding under a clamp.4) Tightening torque: 0.22 N·m / 2 lbf·in5) Tightening torque: 0.5 N·m / 4.4 lbf·inDI3 DI4 Operation (parameter)0 0 Set speed throughintegrated potentiometer1 0 Speed 1 (1202)0 1 Speed 2 (1203)1 1 Speed 3 (1204)3)1…10 kohm |
Related manuals for ABB ACS150 series
ABB ACS180 Quick Installation And Start-up Manual
ABB ACS560 Quick Installation And Start-up Manual
ABB ACS560 Quick Installation And Start-up Manual
ABB ACS480 Quick Installation And Start-up Manual
ABB ACS380 Quick Installation And Start-up Manual
ABB ACS355 Quick Installation And Start-up Manual
ABB ACS355 Quick Installation And Start-up Manual
ABB ACS560 Quick Installation And Start-up Manual
ABB ACS560 Quick Installation And Start-up Manual
ABB ACS380 Quick Installation And Start-up Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine