ABB ACS550 Quick Start Manual
Also see for ACS550 Series: User manualQuick start up guideQuick start guideUser manualQuick start guide
ACS550Quick Start GuideACS550-01 Drives (0.75…160 kW),IP54 / UL Type 12 EnclosureOverviewThe installation of the ACS550 adjustablespeed AC drive follows the outline below.ApplicationThis guide provides a quick reference forinstallations involving: ACS550-01 drives, cableconnections and IP54 / UL type 12 enclosures.Note: This guide does not provide detailedinstallation, safety or operationalinstructions. See ACS550 User’s Manual forcomplete information.Prepare for installationWARNING! The ACS550 should ONLY beinstalled by a qualified electrician.Unpack the driveNote: Lift the ACS550 by its chassis and not by itscover.1. Unpack the drive.2. Check for any damage.3. Check the contents against the order / shippinglabel.Check• Motor compatibility – Motor type, nominalcurrent, frequency and voltage range mustmatch drive specifications.• Suitable environment – Drive requires heated,indoor controlled environment that is suitablefor the selected enclosure.• Wiring – Follow local codes for wiring, circuitprotection and EMC requirements.Refer to User’s Manual and confirm that allpreparations are complete.Drive identificationUse the following chart to interpret the typecode found on the drive label.Collect motor dataCollect the following data from the motornameplate for later use in the ACS550 startup:• Voltage __________________________• Nominal motor current ______________• Nominal frequency _________________• Nominal speed ____________________• Nominal power ____________________Tools requiredScrewdrivers, wire stripper, tape measure,mounting screws or bolts and drill.Prepare the mounting locationThe drive requires asmooth, vertical, solidsurface, free from heat andmoisture, with free space forair flow – 200 mm (8 in)above and below.1. Mark the mounting pointsusing the template.2. Drill the mounting holes.Remove the front cover1. If hood ispresent:Remove screws(2) holding hoodin place.2. If hood ispresent: Slidehood up and offthe cover.3. Loosen thecaptive screwsaround the edgeof the cover.4. Remove thecover.Mount the driveThe holes providing for access to the drivemounting slots require rubber plugs.1. As required for access,remove the rubberplugs. Push plugs outfrom the back of thedrive.2. R5 & R6: Align thesheet metal hood (notshown) in front of thedrive’s top mountingholes. (Attach as part ofnext step.)3. Position the ACS550 and securely tighten in allfour corners.Note: Lift the ACS550 by its metal chassis.4. Reinstall the rubber plugs.5. Non-English speaking locations: Attach awarning sticker in the appropriate languageover the existing warning on the top of themodule.Install the wiringGeneral wiring1. Cut the rubber cableseals as needed for thepower, motor and controlcables. The conical partof the seals must facedownwards wheninserted in the lead-through plate holes.Wiring power1. On the input powercable, strip thesheathing back farenough to routeindividual wires.2. On the motor cable,strip the sheathingback far enough toexpose the copper wire shield so that the shieldcan be twisted into a bundle. Keep the bundlebundle not longer than five times its width tominimize noise radiation. – 360° groundingunder the clamp is recommended for the motorcable to minimize noise radiation. In this case,remove the sheathing at the cable clamp.3. Route both cables through the clamps andtighten the clamps.4. Connect the bundle created from the motorcable shield to the GND terminal.5. Strip and connect the power/motor wires andthe power ground wire to the drive terminalsusing the torques given in the table below. SeePower connections below or, for more detail,see User’s Manual.PREPARE for installationPREPARE mounting locationREMOVE the front coverMOUNT the driveINSTALL wiringCHECK installationREINSTALL the coverAPPLY powerSTART-UPSernoACS550-01-08A8-4*2030700001*U1 3~ 380...480 VI2N/ I2hd 8.8/6.9 APN/Phd 4.0/3.0 kWACS550-01-08A8-4+B055+…AC, Standard Drive – 550 seriesSee Ratings in User’s Manual for detailsConstruction (region specific)Output current ratingVoltage rating2 = 208…240 V AC4 = 380…480 V AC6 = 500…600 V ACExamples of options:No specification = IP21 / UL type 1B055 = IP54 / UL type 12UL type 12 is not available for typeACS550-01-290A-4.0J400 = No control panelJ404 = ACS-CP-C Basic Control Panel01 = Setup/parts for IEC install./complianceU1 = Setup/parts for US install./complianceOptionsX00021341 2FM31, 4FM5Frame size Tightening torqueN·m lb·ftR1, R2 1.4 1R3 2.5 1.8R4 5.6; PE: 2 4; PE 1.5R5 15 11R6 40; PE: 8 30; PE: 61 IP500331IP5004235 |
Related manuals for ABB ACS550 Series
ABB STRIEBEL & JOHN MISTRAL65 Manual
ABB SPB08W Installation Instructions Manual
ABB MISTRAL41F Multimedia Manual
ABB PPKA0400 Instruction Manual
ABB MUL1-R1 Installation Instructions Manual
ABB ACH580-01 VxR R1 Instructions Manual
ABB ACH580-01 PxR R3 Instructions Manual
ABB ACH580-01 PxR Frame R2 Instructions Manual
ABB MISTRAL41W Multimedia Instruction Manual
ABB System pro E power Instruction Handbook Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine