ABB ACS550 Quick Start Manual
Also see for ACS550 Series: User manualQuick start up guideQuick start guideUser manualQuick start guide
ACS550Quick Start GuideACS550-01 Drives (0.75…160 kW),IP21 / UL Type 1 EnclosureOverviewThe installation of the ACS550 adjustablespeed AC drive follows the outline below.ApplicationThis guide provides a quick reference forinstalling ACS550-01 drives having a standardenclosure.Note: This guide does not provide detailedinstallation, safety or operationalinstructions. See ACS550 User’s Manual forcomplete information.Prepare for installationWARNING! The ACS550 should ONLY beinstalled by a qualified electrician.Unpack the driveNote: Lift the ACS550 by its chassis and not by itscover.1. Unpack the drive.2. Check for any damage.3. Check the contents against the order / shippinglabel.Check• Motor compatibility – Motor type, nominalcurrent, frequency and voltage range mustmatch drive specifications.• Suitable environment – Drive requires heated,indoor controlled environment that is suitablefor the selected enclosure.• Wiring – Follow local codes for wiring, circuitprotection and EMC requirements.Refer to User’s Manual and confirm that allpreparations are complete.Drive identificationUse the following chart to interpret the typecode found on the drive label.Collect motor dataCollect the following data from the motornameplate for later use in the ACS550 startup:• Voltage __________________________• Nominal motor current ______________• Nominal frequency _________________• Nominal speed ____________________• Nominal power ____________________Tools requiredScrewdrivers, wire stripper, tape measure,mounting screws or bolts and drill.Prepare the mounting locationThe drive requires asmooth, vertical, solidsurface, free from heat andmoisture, with free space forair flow – 200 mm (8 in)above and below.1. Mark the mounting pointsusing the template.2. Drill the mounting holes.Remove the front cover1. Remove thecontrol panel, ifattached.2. Loosen thecaptive screwat the top.3. Pull near thetop to removethe cover.Mount the drive1. Position the ACS550 anduse screws or bolts tosecurely tighten all fourcorners.Note: Lift the ACS550 by itsmetal chassis.2. Non-English speakinglocations: Attach awarning sticker in the appropriate languageover the existing warning on the top of themodule.Install the wiringWiring power1. Open the appropriateknockouts in the gland box.2. Install the cable clamps forthe power/motor cables.3. On the input power cable,strip the sheathing back farenough to route individual wires.4. On the motor cable,strip the sheathingback far enough toexpose the copper wireshield so that theshield can be twistedinto a bundle. Keep thebundle not longer thanfive times its width to minimize noise radiation.– 360° grounding under the clamp isrecommended for the motor cable to minimizenoise radiation. In this case, remove thesheathing at the cable clamp.5. Route both cables through the clamps.6. Connect the bundle created from the motorcable shield to the GND terminal.7. Strip and connect the power/motor wires andthe power ground wire to the drive terminalsusing the torques given in the table below. SeePower connections below or, for more detail,see User’s Manual.8. Install conduit/gland box and tighten the cableclamps.WARNING! To disconnect the internal EMCfilter, remove the screws marked with “-”, orreplace the screws marked with “ ” with theprovided polyamide screws, depending onthe frame size.9. Install the cable clamp(s) forthe control cable(s). (Power/motor cables and clampsnot shown in the figure.)PREPARE for installationPREPARE mounting locationREMOVE the front coverMOUNT the driveINSTALL wiringCHECK installationREINSTALL the coverAPPLY powerSTART-UPSernoACS550-01-08A8-4*2030700001*U1 3~ 380...480 VI2N/ I2hd 8.8/6.9 APN/Phd 4.0/3.0 kWACS550-01-08A8-4+J404+…AC, Standard Drive – 550 seriesSee Ratings in User’s Manual for detailsConstruction (region specific)Output current ratingVoltage rating2 = 208…240 V AC4 = 380…480 V AC6 = 500…600 V ACExamples of options:No specification = IP21 / UL type 1B055 = IP54 / UL type 12UL type 12 is not available for typeACS550-01-290A-4.0J400 = No control panelJ404 = ACS-CP-C Basic Control Panel01 = Setup/parts for IEC install./complianceU1 = Setup/parts for US install./complianceOptionsX000213IP200012IP200212Framesize Tightening torqueN·m lb·ftR1, R2 1.4 1R3 2.5 1.8R4 5.6; PE: 2 4; PE 1.5R5 15 11R6 40; PE: 8 30; PE: 6System type R1...R3 R4 R5...R6EM1 EM3 EM1 EM3 F1 F2IT system - - - -Corner grounded TNsystem -12X00043IP200148677X000589 X0006 |
Related manuals for ABB ACS550 Series
ABB ACS880 Quick Start Up Manual
ABB ACS880 Quick Start Up Manual
ABB ACS580 Series Quick Start Manual
ABB ACS355 UL 4X Quick Start Manual
ABB ACS850 Series Quick Start Up Manual
ABB DCS550-S01 Quick Manual
ABB ACS580MV Quick Manual
ABB ACS580MV Quick Manual
ABB ACH580 Series Quick Start Up Manual
ABB ACS560 Quick Installation And Start-up Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine