|
KNX Technical Reference Manual | 0073-1-7388 | 39Pos: 22.78 /Produkthandbuch - DIN-A4/Überschriften/2. Ebene/G - L/LED-Funktion @ 9\mod_1269508367126_15.doc @ 53030 @ 2LED functionPos: 22.79 /KNX/Applikationsbeschreibungen/Applikationen - App/LED Funktion/App. - LED-Funktion - DIN-A4 @ 9\mod_1269508113996_15.doc @ 53025 @With the "LED function" application, the LED of the rocker can be used for orientation lighting, for status indication or forfunction display. The LED can light up in different colours. The LED can also flash for alarm display and/or scene storagedisplay.LED function objectsNo. Object name Data type Flags0 Status (1 Bit) 1 Bit EIS1 / DPT 1.001 C, W, U0 Status (1 Byte 0..100 %) 1 Bit EIS6 / DPT 5.001 C, W, U1 Day / Night mode (1 Bit) 1 Bit EIS1 / DPT 1.001 C, W, U2 Proximity (1 Bit) 1 Bit EIS1 / DPT 1.001 C, W, U3 Alarm (DPT_Alarm) 1 Bit / DPT_Alarm C, W, U4 Scene storage (DPT_Scene_Control) 1 Byte / DPT 18.001 C, W, UPos: 22.80 /Produkthandbuch - DIN-A4/Überschriften/2. Ebene/A - F/Alarmfunktion @ 9\mod_1269508521119_15.doc @ 53071 @ 2Alarm functionPos: 22.81 /KNX/Applikationsbeschreibungen/Applikationen - App/Alarmfunktion/App. - Alarmfunktion - DIN-A4 @ 9\mod_1269508449466_15.doc @ 53056 @If the alarm function is switched active, the LED can be made to flash (1 Hz) during the status or function display via a 1-bit"Alarm" communication object.The LED will flash if an ON telegram is received on a 1-bit "Alarm" communication object. If the object receives an OFFtelegram, the LED will no longer flash.The LED always flashes in the same colour and brightness that was specified via the status function or function display.The alarm function could, for example, be used to display a wind alarm to the user to let the user know that no blindoperation is possible at that time. An additional application would be the signalling of an open door when the user would liketo lower a roller blind.Hint:If the LED is currently serving as an orientation light, it will not flash. This also applies if it is switched to orientation lightingduring flashing, i.e. the LED stops flashing immediately.Pos: 22.82 /Produkthandbuch - DIN-A4/Überschriften/2. Ebene/S - T/Speicherfunktion Lichtszenen @ 9\mod_1269508749593_15.doc @ 53082 @ 22Light scene memory functionPos: 22.83 /KNX/Applikationsbeschreibungen/Applikationen - App/Speicherfunktion Lichtszenen/App. - Speicherfunktion Lichtszenen - DIN-A4 @ 9\mod_1269508652816_15.doc @ 53077 @If the "Light scene memory function" is switched active, the LED can be made to flash (3 Hz) via a 1-bit communicationobject "Scene storage" during the status or function display.If a scene storage telegram is received on the 1-byte communication object "Scene storage", the LED will blink for 3 s andthen stop blinking automatically.The LED always flashes in the same colour and brightness that is specified via the status function or function display.Hint:If the LED is currently serving as an orientation light, it will not blink. This also applies if orientation illumination is switchedto during flashing.Pos: 22.84 /Spezial/Neues Layout 2010/Steuermodule_Neues_Layout_2010/++++++++++++ Seitenumbruch ++++++++++++ @ 9\mod_1268898668093_0.doc @ 52149 @
PreviousNext |