F O X C S T R E F E R E N C E34 FOX61xLEDE18.3 AP: / unit-x / port-y8.3.1 AP: / unit-x / port-y, OverviewFor a description of the− “Overview - Alarms”, and− “Overview - Cross Connections”management functions, please refer to "1KHW002466 FOXCST Operation".8.3.2 AP: / unit-x / port-y, Main8.3.2.1 AP: / unit-x / port-y, Main - GeneralFor a description of the− “Main - General”management function, please refer to "1KHW002466 FOXCST Operation".NSW No Application Soft-wareEquipmentAlarm Major There is no application ESW installed onthe unit, or the application ESW has notyet finished its boot process.UNAS Unit Not Assigned EquipmentAlarm Warning The unit is not assigned and cannot beconfigured. To assign the unit, executethe “Assign” command in the “Main”function of the unit.UIC Unit Incompatible EquipmentAlarm Major The inserted unit is not compatible withthe assigned unit.PWRSVE Battery Power Saving EquipmentAlarm Critical Power saving is active on the unit, i.e. itis kept in the “reset” state during batterypower backup.Table 8: AP: / unit-x, Fault Management (continued)ID Fault Cause Event Type TrafficAffectingDefaultSeverityDescription