Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- Preface
- Document history
- Introduction
- Unit view
- Functions and specifications
- Installation
- Previous ESW revisions
- x 2 Mbit/s cable 120 Ω
- Figure 4: Side view of the cable tray and the cable in FOX615
- Functional description
- Transparent transport modes
- Protection
- Commissioning
- Commissioning of an E1 port
- Operation and maintenance
- Loops
- Maintenance
- FOXCST reference
- AP: / unit-x: LEDE1
- AP: / unit-x, Fault Management
- AP: / unit-x / port-y
- AP: / unit-x / port-y, Main - Admin And Oper Status
- AP: / unit-x / port-y, Configuration - General
- AP: / unit-x / port-y, Configuration - Synchronization
- AP: / unit-x / port-y, Configuration - Channels
- AP: / unit-x / port-y, Fault Management
- AP: / unit-x / port-y, Performance Management - G.826
- AP: / unit-x / port-y, Status
- AP: / unit-x / port-y, Status - QL
- AP: / unit-x / port-y / chan-z, Main - Admin And Oper Status
- AP: / unit-x / port-y / chan-z, Fault Management
- AP: / unit-x / port-y / chan-z, Performance Management - Protection
- Annex
|
F O X C S T R E F E R E N C E40 FOX61xLEDE18.3.4 AP: / unit-x / port-y, Fault ManagementFor the a description of the general aspects of the− “Fault Management - Status”, and− “Fault Management - Configuration”management functions, please refer to "1KHW002466 FOXCST Operation".The following counter groups are available for the LEDE1 E1 ports:• “G.826” group, see section "AP: / unit-x / port-y, Performance Manage-ment - G.826" (page 41).• “P12 Events” group, see section "AP: / unit-x / port-y, Performance Man-agement - P12 Events" (page 41).The following counter intervals are available, depending of the countergroup:Create MultipleChannelsStart Index 0 … 32 The start index is the channel index of the firstchannel.0 is a reserved value used for the auto-assign-ment of a channel index: The auto-assignedindex is the highest existing index number + 1.In the FOXCST the default value is the autoas-signed index number.Number Of Chan-nels1 … 32 Number of channels to be created.If the configured number of channels to be cre-ated is higher than the available number ofunused time slots, the FOXCST creates nochannel, and displays a corresponding errormessage.n 1 … 32 Number of consecutive timeslots. If the struc-tured P12 signal, the channel is belonging to,uses CAS the timeslot 16 will be skipped auto-matically, e.g. a channel with n = 19 and starttimeslot 1 will occupy timeslots 1 to 15 and 17 to20 in a PCM30 signal.The default value is the maximum of availabletimeslots.The start timeslot of the first channel is the low-est available timeslot number.Delete Channel … Open the FOXCST dialogue to delete one or allchannels.Delete Channel Delete Channel All Delete all channels.All connections assigned to the channels will bedeleted also.chan-1 … chan-31 Delete a channel.All connections assigned to the channel will bedeleted also.Table 12: AP: / unit-x / port-y, Configuration - Synchronization (con-Operation Name Parameter Name Range Description / DetailsTable 13: PM counter interval availabilityCounter interval G.826 P12 EventsUser Counter yes yes
PreviousNext |