Parameterization92 FSM4000 D184B140U02Pos: 35.6 /Überschriften/1.1.1/1-spaltig/Darstellung der Diagnosewerte in der Displayanzeige @ 16\mod_1196850459000_3101.doc @ 1444897.4.2 Displaying the diagnostic valuesPos: 35.7 /Konfiguration, Parametrierung/Durchfluss/FSM4000/Erweiterte Diagnosefunktionen/Darstellung der Diagnosewerte @ 16\mod_1196850583578_3101.doc @ 1445127.4.2.1 Measurement valuesA maximum of four diagnostic values can be displayed (Fprt1, Fprt2, Fprt3, Fprt4). Values canbe selected in the submenu Diagnostics / Fingerprint / Fprt1 - 4. In addition to the type ofmeasurement value, the desired data record has to be configured. Through the combination ofthese two settings, every stored measured value can be displayed. To differentiate between thevalues in the display an identification code (ID) is prefixed before to each value.As a result, each line appears as follows:e.g., CV_RCL 80.5 ohm for the current coil resistance.CV _ RCL 80.5 ohmData record Type Numerical value UnitCV_: Current value UAC: Coil voltage (AC) X.X VH1_: History 1 IAC: Coil current (AC) X mAH2_: History 2 RCL: Coil resistance Value > 100 XValue < 100 X.XOhmH3_: History 3 TCL: Coil temperature X °CH4_: History 4 RIS: Insulation resistance Value > 100 XValue < 100 X.XMOhmH5_: History 5 UE1: Electrode voltage E1 X μVH6_: History 6 UE2: Electrode voltage E2 X μVH7_: History 7 BAL: Electrode balance E1 ≥ E2 → +XE1 < E2 → -X%%H8_: History 8 LIN: Magnetic linearity X %H9_: History 9 SNR: Signal-to-noise ratio X %FV_: Factory Fingerprint DAC: Max. DAC value X Dig =DigitsDF_: Startup FingerprintP1_: Product 1-FingerprintP2_: Product 2-Fingerprint