Contents - Table Of Contents
- Table Of Contents
- Table Of Contents
- General
- Notes
- Product and functional overview
- Functional overview
- Device technology
- Valve outputs (thermoelectric, PWM)
- Resolution, accuracy and tolerances
- Fan, rated current 6 A
- Fan, lamp load 6 A
- Output, rated current 16 A
- Output, lamp load 16 A
- Connection diagram (motor-driven, 3-point)
- Dimension drawing
- Fan Coil Actuator FCA/S 1.1.2.2, PWM, MDRC
- Output, rated current 20 AX
- Output, lamp load 20 AX
- Connection diagram (thermoelectric, PWM)
- Fan Coil Actuator FCA/S 1.2.1.2, 0-10V, MDRC
- Outputs, valve V1/2, analog
- Connection diagram
- Fan Coil Actuator FCA/S 1.2.2.2, 0-10V, MDRC
- Mounting and installation
- Manual operation
- Display elements
- Operating controls
- Commissioning
- Functions of the inputs
- Output functions
- Parameters
- Parameter window General – Settings
- Parameter window Manual operation – Settings
- Parameter window Outputs A...H
- Description of the Fan Coil operating modes with valve drive, thermoelectric (PWM)
- Description of the Fan Coil operation modes with valve drive motor-driven (3-point) and analog
- Parameter window A: Output (Valve drive, thermoelectric (PWM))
- Parameter window AB: Output (valve drive, motor-driven (3-point))
- Parameter window A: Output (valve drive, analog (0...10 V))
- Parameter window Function
- Parameter window Security
- Parameter window Characteristic curve
- Parameter window Output B, C, D
- Parameter window Enable output E...H
- Parameter window E, F, G: Fan (Multi-level)
- Parameter window Status messages (Multi-level)
- Parameter window Thresholds (Multi-level)
- Parameter window Automatic control (Multi-level)
- Parameter window Direct operation (Multi-level)
- Parameter window Startup/Run-on
- Parameter window E, F, G: Fan (Two-level)
- Parameter window E, F, G: Fan (One-level)
- Parameter window Status messages (single speed)
- Parameter window Threshold (One-level)
- Parameter window Automatic control (One-level)
- Parameter window E, F, G: Output (switch actuators)
- Parameter window H: Output
- Parameter window Time
- Parameter window Inputs a...c
- Parameter window a: Switch sensor
- Parameter
Distinction between long and short operation – No
- Parameter Distinction between long and short operation – Yes
- Parameter window a: Value/forced operation
- Parameter window a: PT100, PT1000 and KTY
- Parameter options for KTY
- Line fault compensation Via cable length
- Line fault compensation Via cable resistance
- Parameter window a: Threshold 1
- Parameter window a: Threshold 1 Output
- Communication objects
- Communication objects General
- Communication objects Valve drive, thermoelectric (PWM) and motor-driven (3-point)
- Communication objects Fan E, F, G
- Communication objects Fan One-level
- Communication objects Switch actuators E, F, G
- Communication objects Output H
- Communication objects Inputs a...c
- Communication objects Switch sensor
- Communication objects Value/forced operation
- Communication objects Temperature sensor
- Communication objects Heating/Cooling
- Planning and application
- Fan output
- Fan with changeover switch
- Direct operation
- Speed switching logic
- Fan operation functional diagram
- Switch output
- Time function
- Valve drives, valves and controller
- Control types
- Pulse width modulation (PWM)
- Pulse width modulation – calculation
- Reaction on bus voltage failure, recovery, download and ETS reset
- ETS reset
- Priorities
- A Appendix
- A.2 Status byte General
- A.3 Status byte outputs A, B, C, D
- A.4 Status byte fan
- A.5 Ordering details
- A.6 Notes
|
ABB i-bus® KNXCommissioningFCA/S 1.x.x.1 | 2CDC508134D0202 1953.2.4.4.2 Parameter options for KTYThis parameter window is visible if the option KTY has been selected in the parameter Input a inParameter window Enable inputs a…c, p. 170.Manufacturer designationOptions: KT 100 / 110 / 130KT 210 / 230KTY 10-5 / 11-5 / 13-5KTY 10-6 / 10-62 / 11-6 / 13-6 / 16-6 / 19-6KTY 10-7 / 11-7 / 13-7KTY 21-5 / 23-5KTY 21-6 / 23-6KTY 21-7 / 23-7KTY 81-110 / 81-120 / 81-150KTY 82-110 / 82-120 / 82-150KTY 81-121 / 82-121KTY 81-122 / 82-122KTY 81-151 / 82-151KTY 81-152 / 82-152KTY 81-210 / 81-220 / 81-250KTY 82-210 / 82-220 / 82-250KTY 81-221 / 82-221KTY 81-222 / 82-222KTY 81-251 / 82-251KTY 81-252 / 82-252KTY 83-110 / 83-120 / 83-150KTY 83-121KTY 83-122KTY 83-151User-definedFor selection of a predefined KTY sensorNoteIf a KTY sensor which is not in the list is used, the option KTY user-defined can be used to enter itscharacteristic (see following page).
PreviousNext |