ABB i-bus ® KNXGeneralDGN/S 1.16.1 | 2CDC 507 114 D0201 31 GeneralThis manual provides you with detailed technical information relating to the group-orientated ABB i-bus®KNX DALI Gateway with Emergency Lighting Function DGN/S 1.16.1. The installation, programming andcommissioning and the device are described using examples. Furthermore, basic terminology used withemergency lighting technology is explained.The DGN/S is used for control of DALI equipment, e.g. ballasts, transformers or LED converters with DALIinterfaces compliant to EN 62386 via KNX. Furthermore, DALI self-contained emergency lighting (devicetype 1) with individual batteries can be integrated to EN 62386-202.Here the DGN/S 1.16.1 itself does not offer a functionality in terms of the emergency lighting regulations,e.g. protocoling functions or other associated stipulated functions. It serves as an intelligent mediator be-tween KNX and DALI.The different mandatory tests for emergency lighting, e.g. functional tests or duration testing, can be trig-gered via KNX, and the result can be provided again on the KNX via communication objects.The DGN/S combines both the internationally standardized and open standards in the digital illuminationcontrol DALI (EN 62386) and intelligent installation system KNX (ISO/IEC 14543-3 and EN 50090).