Y1-03-0232F 6Surface MountInstall the surface mount Point Pad™ by drillingthree (3) holes in the dashboard location usingthe Point Pad™ Surface Mount Templatesupplied in the Mounting Templates. Mount thePoint Pad to the dashboard using the gasket,washers and nuts supplied. Apply a sealantaround the bolt holes to protect from moistureintrusion.Flush MountWhen the flush mount is selected, cut arectangular hole in the dashboard location usingthe Point Pad™ Flush Mount Template supplied inthe Mounting Templates. Use the gasket, washers,nuts and the two U-Clamps provided to secure thePoint Pad™. Apply a sealant around the cut out toprotect from moisture intrusion.Connecting to the Master ControllerThe Point Pad™ communicates with the Master Controller via standardtelevision type RG-59 coaxial cable. The connectors are standard “F”type television connectors. The connector on the back of the PointPad™ is located in the center of the panel for ease of installation. Afterthe coax cable has been routed and the “F” connector is attached to thecoax cable, screw the “F” connectors to the Master Controller and thePoint Pad™.Additional Point Pads™ (up to three) may be used with one (1) MasterController. A standard “T” connector or RG-59 television type splitter isused for each additional Point Pad™. Limit the total length of all coaxcable used to 300 feet.URP-102Surface MountURP-102Flush Mount