11Section 61245207L2-5, Issue 261245207L2-5CFigure 11 depicts the Self-Test Options Screen. Atest of the FT1-DP and the FNID may be initiatedfrom this screen.Figure 12. Provisioning Options ScreenPROVISIONING___________________________________________________ ______________________| | || PROVISIONS CURRENT SETTINGS | HARDWARE SETTINGS || ------------------------------------------ | ----------------- || 1. DS1 (FNID) LINE CODE = B8ZS | B8ZS || 2. DS1 (FNID) FRAMING = ESF | ESF || 3. DS1 (FNID) TX LEVEL = 0 dB | || 4. LOOPBACK TIMEOUT = 20 MIN | 20 MIN || 5. LATCHING LOOPBACK = ENABLED | ENABLED || 6. DSO SEQUENCE = CONTIGUOUS | CONTIGUOUS || 7. NUMBER OF DSOS = 12 (768Kbps) | 12 (768Kbps) || 8. SIGNALING ENABLED: | || 000000000000 | 000000000000 || CHANNELS 1 12 | 1 12 || “1” INDICATES SIGNALING ENABLED. | ||___________________________________________________|______________________|Press: “n” — to change corresponding provision (ex. “2” for FRAMING)“H” — to copy hardware settings to current settings“I” — to implement and save current setting changes“M” — to return to the main menuFigure 11. Self-Test Options ScreenSELF-TESTPress “S” to initiate FT1-DP and FNID self-tests.Press “M” to return to the Main Menu.Figure 12 shows the Provisioning Options screen.Settings for all provisioning options may beconfigured via the provisioning screen.