ADTRAN NetVanta T1/FT1 + DSX-1 Quick Start Manual
Contents |
NetVanta T1/FT1 + DSX-1 Network Interface Module (NIM) P/N 1202863L1For more detailed documentation, visit us online at www.adtran.com.Quick Start Guide®Quick Start Guide, 61200863L1-13D, July 2005 Technical Support 1-888-4ADTRAN (1-888-423-8726) Copyright © 2005 ADTRAN, All Rights ReservedT1/FT1 + DSX-1 NIM COMMANDSclock source [internal | line* | through]Configures the source timing used for the interface. Use the no form of this command to returnto the default value.internal Configures the unit to provide clocking using the internal oscillator.line* Configures the unit to recover clocking from the T1 circuit.through Configures the unit to recover clocking from the circuit connected tothe DSX-1 interface.coding [ami | b8zs*]Configures the line coding for a T1 physical interface. This setting must match the line codingsupplied on the circuit by the service provider.ami Configures the line coding for alternate mark inversion (AMI).b8zs * Configures the line coding for bipolar eight zero substitution (B8ZS).fdl [ansi* | att | none]Configures the format for the facility data link (FDL) channel on the T1 circuit. Use the no formof this command to return to the default value.ansi * Configures the FDL for ANSI T1.403 standard.att Configures the FDL for AT&T TR 54016 standard.none Disables FDL on this circuit.framing [d4 | esf*]Configures the framing format for the T1 interface. This parameter should match the framingformat supplied by your network provider. Use the no form of this command to return to thedefault value.d4 Specifies D4 superframe (SF) format.esf * Specifies extended superframe (ESF) format.lbo [long <-22.5, -15, -7.5- 0> | short <0 to 655>]Configures the line build out (LBO) for the T1 interface. Use the no form of this command toreturn to the default value.long <-22.5, -15, -7.5-0> Configures the LBO (in dB) for T1 interfaces with cable lengthsgreater than 655 feet. Choices are -22.5, -15, -7.5, and 0 dB.short<0 to 655> Configures the LBO (in feet) for T1 interfaces with cable lengths lessthan 655 feet. Range is 0 to 655 feet.loopback network [line | payload]Initiates a loopback on the interface toward the network. Use the no form of this command todeactivate the loopback.line Initiates a metallic loopback of the physical T1 network interface.payload Initiates a loopback of the T1 framer (CSU portion) of the T1 networkinterface.loopback remote line [fdl | inband]Sends a loopback code to the remote unit to initiate a line loopback. Use the no form of thiscommand to send a loopdown code to the remote unit to deactivate the loopback.fdl Uses the facility data link (FDL) to initiate a full 1.544 Mbps physical(metallic) loopback of the signal received by the remote unit from thenetwork. (T1 interface only.)inband Uses the inband channel to initiate a full 1.544 Mbps physicalphysical (metallic) loopback of the signal received from the network.loopback remote payloadSends a loopback code to the remote unit to initiate a payload loopback. A payload loopback isa 1.536 Mbps loopback of the payload data received from the network maintaining bit-sequence integrity for the information bits by synchronizing (regenerating) the timing. Use theno form of this command to send a loopdown code to the remote unit to deactivate theloopback.remote-alarm [rai]Selects the alarm signaling type to be sent when a loss of frame is detected on the T1 receivesignal. Use the no form of this command to disable all transmitted alarms.rai Specifies sending a remote alarm indication (RAI) in response to aloss of frame. Also prevents a received RAI from causing a change ininterface operational status.remote-loopbackConfigures the interface to respond to loopbacks initiated by a remote unit (or serviceprovider). Use the no form of this command to disable this feature.show test-patternDisplays results from test patterns inserted using the test-pattern command.signaling-mode [message-oriented | none | robbed-bit*]Configures the signaling type (robbed-bit for voice or clear channel for data) for the DS0smapped to the DSX-1 port.message-oriented Specifies clear channel signaling on Channel 24 only. Use thissignaling type with QSIG installations.none Specifies clear channel signaling on all 24 DS0s. Use this signalingtype with data-only or PRI DSX-1 installations.robbed-bit* Specifies robbed bit signaling on all DS0s. Use this signaling type forvoice-only DSX-1 applications.snmp trap link-statusControls the Simple Network Management Protocol (SNMP) variableifLinkUpDownTrapEnable (RFC2863) to enable (or disable) the interface to send SNMP trapswhen there is an interface status change. Use the no form of this command to disable thistrap.tdm-group |
Related manuals for ADTRAN NetVanta T1/FT1 + DSX-1
ADTRAN NetVanta T1/FT1+DSX-1 Quick Start Manual
ADTRAN NetVanta 2300 Quick Start Manual
ADTRAN NetVantaE1/FE1 Quick Start Manual
ADTRAN NETVANTA 6355 Quick Start Manual
ADTRAN NetVanta 6360 Quick Start Manual
ADTRAN NetVanta 4660 Quick Start Manual
ADTRAN NetVanta 1760-12F Quick Start Manual
ADTRAN NetVanta NetVanta ADSL NIM Quick Start Manual
ADTRAN NetVanta 1200864L1 Quick Start Manual
ADTRAN NETVANTA OCTAL POE Quick Start Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine