BURNER NORMAL POWERkWNatural GasINJECTOR MARK 1/100mmBtu/hTriple Crown 3.4 136 11600Grill 2.7 122 9212Top Oven 1.7 95 5804Main Oven 1.7 95 580413.7 Gas ConnectionUse a flexible pipe in compliance withthe regulation in force. Make sure theydo not come in touch with mobile partsand are not squeezed.WARNING!Only a qualified andcompetent person can dothe gas installation.Before you connect te gas,disconnect the appliancefrom the electricity supply orswitch off the fuse in the fusebox. Close the primary valveof the gas supply.Supply piping should not beless than R3/8. Connection ismade to the Rc 1/2 (1/2“ B.S.P.) female threaded.The entry pipe is located justbelow the hob level on therear left hand side of theappliance.The gas supply ramp is onthe rear side of theappliance.WARNING!Only liquid sealants can beused when the inlet gas pipeis fitted i.e.: do not use theP.T.F.E. sealant tape.When the installation iscomplete, carry out a gastightness test and make surethat the seal of each pipefitting does not leak.Use flexible tubing, whichcomply with the BS.669current edition.ABCCDEWARNING!The gas bayonet connectormust be in the marked area.Dimension mmA 250B 680C 50D 250E 580ENGLISH 27