11Instruction for the InstallerEngineers technical dataBURNER RAPID SEMI-RAPID AUXILIARY TRIPLE(large) (medium) (small) CROWNPOSITION M A X MIN M A X MIN M A X MIN MAX MINNOMINAL THERMALPOWER (kW) 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2NOMINAL FLOWRATE (m 3 /h) 0.266 0.062 0.190 0.043 0.095 0.028 0.381 0.114NOZZLE REFERENCE 113 Adjust. 96 Adjust. 70 Adjust. 146 Adjust.(1/100 mm)NOMINAL THERMALPOWER (kW) 2.8 0.65 2.0 0.45 1.0 0.33 4.0 1.2NOMINAL FLOWRATE (g/h) 202 47 144 32 72 24 288 86NOZZLE REFERENCE 86 40 71 32 50 28 98 56(1/100 mm)NATURAL GAS20 mbarVALUE =37.78 MJ/m 3Ws - 50.7 MJ/ m 3TYPE OF GASLPG GAS28-30/37 mbarVALUE =49.92 MJ/KgBurner Dia. Tap By-pass1/100 mmAuxiliary 28Semi-rapid 32Rapid 40Ultra-rapid 56Aeration adjustment noneSupply ConnectionsGas:R 1/2 inch (1/2 inch male) Rear right handcornerElectric: 230 V 50 Hz supply, 3 core flexiblecable with non rewireable plug fitted with a 3amp cartridge fuse.Overall dimensionsWidth: 680 mmDepth: 510 mmCut out dimensionsWidth: 560 mmDepth: 480 mmHeat InputUltra-rapid Burner 4.0 kW (13652 BTU/HR)Rapid Burner 2.8 kW Natural Gas(10239 BTU/HR)2.8 kW L.P.G.(9556 BTU/HR)Semi-rapid Burner 2.0 kW (6824 BTU/HR)Auxiliary Burner 1.0 kW (3413 BTU/HR)Appliance class 3Appliance category II2H3+Gas supply Natural gas G20 / 20mbar