33Replacing the injectors1. Remove the pan supports.2. Remove the burner caps and crowns.3. Using a 7 mm socket spanner unscrew andremove the injectors, then replace themwith the ones required for the new typeof gas (see the table “Burnercharacteristics”).4. Reassemble the parts, following thesame procedure backwards.5. Replace the Gas Type Label (located nearthe gas supply connection) with the onecorresponding to the new type of gas. Thelabel is supplied in the accessories plasticbag.Should the feeding gas pressure be different orvariable compared with the required pressure,an appropriate pressure regulator must be fittedon the gas supply pipe, in compliance with therules in force.Conversion to LPGGAS BURNER INJECTOR NOMINAL REDUCED NOMINAL FEEDINGTYPE TYPE REFERENCE THERMAL THERMAL FLOW RATE PRESSURE1/100 mm POWER POWERkW kW m3/h g/h mbarRapid 119 2.9 0.65 0.276Semirapid 96 1.9 0.45 0.181 - 20Auxiliary 70 1.0 0.33 0.095 -Rapid 86 2.7 0.65 - 196Semirapid 71 1.9 0.45 - 138 28-30/37Auxiliary 50 1.0 0.33 - 73NATURALGAS( G 2 0 )LIQUIDGAS(Butane/Propane)Burner characteristics