3. Set the hose correctly by loosening the ring nut.After positioning the inlet hose, be sure to tightenthe ring nut again to prevent leaks.4. Connect the hose to a tap with a 3/4” thread.Always use the hose supplied with the appliance.Installation should comply with local water authorityand building regulations requirements. A minimumwater pressure of 0.05 MPa is required for safeoperation of the appliance.If you cannot make the cold water connection direct from the rising mains, youmay be able to operate the appliance from your cold water storage system. Thereshould be a minimum distance of between the appliance’s inlet and the bottom ofthe water storage tank.Water-stop deviceThe inlet hose is provided with a water stop device,which protects against damage caused by water leaks inthe hose which could develop due to natural ageing ofthe hose. This fault is shown by a red sector in thewindow “A”. Should this occur, turn the water tap off andrefer to your Service Centre to replace the hose.Water drainageThe end of the drain hose can be positioned in three ways:Hooked over the edge of a sink using theplastic hose guide supplied with the machine.In this case, make sure the end cannot comeunhooked when the machine is emptying.This could be done by tying it to the tap with a pieceof string or attaching it to the wall.In a sink drain pipe branch. This branch must beabove the trap so that the bend is at least 60 cm abovethe ground.Directly into a drain pipe at a height of not less than 60 cm and not morethan 90 cm.The end of the drain hose must always be ventilated, i.e. the inside diameter ofthe drain pipe must be larger than the outside diameter of the drain hose.The drain hose must not be kinked.43InstallationOfrecido por www.electromanuales.com