AA. Rigid copper pipe or flexible pipe ofstainless steelIf the pilot lights turn on afterconnecting the hob to themains, turn on and off thecontrol knob and wait untilthe residual heat indicatorgoes out.3.6 Connection cableTo replace the connection cable use onlythe special cable or its equivalent. Thecable type is: H03V2V2-F T90.Make sure that the cable section isapplicable to the voltage and the workingtemperature. The yellow / green earthwire must be approximately 2 cm longerthan the brown (or black) phase wire.LN1. Connect the green and yellow (earth)wire to the terminal which is markedwith the letter 'E', or the earth symbol, or coloured green and yellow.2. Connect the blue (neutral) wire to theterminal which is marked with theletter 'N' or coloured blue.3. Connect the brown (live) wire to theterminal which is marked with theletter 'L'. It must always be connectedto the network phase.3.7 Assembly1.2.3.min.55 mmmin.650 mm560 mm20+480 mm20+min.100 mm30 mm4.www.aeg.com10