10 818 42 69-00/2InstallationInstallation LocationThe appliance should be installed in a well ventilated, dry room.Energy use is affected by the ambient temperature.The appliance should therefore– not be exposed to direct sunlight;– not be installed next to radiators, cookers or other sources of heat;– only be installed at a location whose ambient temperaturecorresponds to the climate classification, for which the appliance isdesigned.The climate classification can be found on the rating plate, which islocated at the left on the inside of the appliance.The following table shows which ambient temperature is correct foreach climate classification:If installation next to a source of heat is unavoidable, the followingminimum clearances must be maintained at the sides of the appliance:– for electric cookers 3 cm;– for oil and coal fired ranges 30 cm.If these clearances cannot be maintained a heat insulating pad isrequired between the cooker and the refrigeration appliance.Climate classification for an ambient temperature ofSN +10 to +32 °CN +16 to +32 °CST +16 to +38 °CT +16 to +43 °C