bdi Access JTAG interface library, BDI1000 (ARM7/9/9E) Installation Manual 8© Copyright 1992-2008 by ABATRON AG V 1.022.2.2 Power Supply from Target SystemThe BDI1000 needs to be supplied between 2.5V and 5V via TARGET A connector. This mode canonly be used when the target system runs between 2.5V and 5V and the pin «Vcc Target» is able todeliver a current up to:• 900mA@2.5Vcc Target• 700mA@3.3Vcc Target• 450mA@5.0Vcc TargetFor pin description and layout see chapter 2.1 «Connecting the BDI1000 to Target». Insert the en-closed Jumper as shown in figure below. Please ensure that the jumper is inserted correctly.For error-free operation, the power supply to the BDI1000 must be between 2.5V and 5V DC. Themaximal tolerable supply voltage is 5.25 VDC. Any higher voltage or a wrong polarity mightdestroy the electronics.!POWER Connetcor1 - Vcc BDI1000 (+2.5 ... +5V)2 - Vcc Target (+2.5 ... +5V)3 - GROUND4 - NOT USEDThe green LEDs «BDI» and «TRGT» marked light up when target is powered upand the jumper is inserted correctlyRS232 LI POWER 10 BASE-T1234TARGET A TARGET BBDITRGTMODEJumper3591 - Reserved2 - TRST3 - GROUND4 - TCK5 - GROUND6 - TMS7 - RESET8 - TDI9 - Vcc Target10 - TDOTarget A Connector