Absolute Process Instruments Cecomp F16AD Instructions Manual
How to Specify TypeF16AD range - options Standard housingF16ADBL range - options Standard housing,backlit displayF16ADN range - options NEMA 4X housingF16ADNBL range - options NEMA 4X housing,backlit displayCecomp® Low-Voltage Powered Digital Pressure Gauges with Selectable Units F16AD, F16ADNRanges and ResolutionSee table below. Select range and default engineering units.Units may be changed to any listed under the same sensor rangeResolution is fixed and limited to available display digitsAccuracyAccuracy includes linearity, hysteresis, repeatabilityStandard accuracy: ±0.25% of full scale ±1 least significant digitHA accuracy option: ±0.1% FS ±1 LSD, see ranges for availabilitySensor hysteresis: ±0.015% FS, included in accuracySensor repeatability: ±0.01% FS, included in accuracyDisplay3 readings per second nominal display update rate4 digit LCD, 0.5" H and 5 character 0.25" H alphanumericBL: Red LED backlight on when gauge is onPower8-24 VAC 50/60 Hz or 9-32 VDCAD: Approximately 5 mAADBL: Approximately 80 mA3 ft long, 2-conductor 22 AWG cableAll models are designed for continuous operationOrder optional WMPSK 115V/12 VDC wall mount power supply kit.Controls and FunctionsFront button turns gauge on or off, zeros gauge reference gauges,and cycles through min./max. functionsInternal buttons for pass code protected unit selection, min./max.setup, calibration.Min/Max FunctionsMinimum and maximum readings stored 3 times per secondFront button cycles through min. display, max. display, clearConfigurable for min. only, max. only, min./max., or noneConfigure to clear or retain min/max values at power offO ±0.25% Test Gauge AccuracyO 316 Stainless Steel Wetted PartsO Minimum, Maximum, Zero FunctionsO Selectable UnitsO Low Voltage PoweredCalibrationPass code protected calibrationNon-interactive zero, span, and linearity, ±10% of rangeWeightGauge: 9 ounces (approximately)Shipping: 1 pound (approximately)HousingF16AD: Extruded aluminum case, epoxy powder coated, ABS/polycarbonate bezel (aluminum bezel optional), front and reargaskets, polycarbonate labelF16ADN: ABS/polycarbonate NEMA 4X case, rear gasket, polycar-bonate labelConnection and Material1/4" NPT male fitting, 316L stainless steelAll wetted parts are 316L stainless steelOverpressure, Burst, VacuumRanges using 3000 psig sensor: 5000 psigRanges using 5000 psig sensor: 7500 psigAll others: 2 X pressure range3000 psi, 5000 psi, and 4 digit ranges 112.5% full scale out-of-range display: 1– – – or I –.–.–.–4 X sensor burst pressure rating, or 10,000 psi, whichever is lessVacuum service: 15 psia, ±15 psig, 15 psig, 30 psia,100 psig, 100 psia, 200 psig sensorsUnder-range display (non-vacuum sensors): –ErrEnvironmentalStorage temperature: –40 to 203°F (–40 to 95°C)Operating temperature: –4 to 185°F (–20 to 85°C)Compensated temperature: 32 to 158°F (0 to 70°C)F16ADOptions—add to end of model numberHAHigh accuracy, ±0.1% FS ±1 LSD.Not available with 3 psi, 5 psi, bipolar, or vacuum sen-sors. See table at left for availability.PM Panel mount, 4.1" x 4.1". Not avail. with NEMA models.MC Metal front cover. Not available with NEMA models.CC Moisture resistant circuit board conformal coatingTP Top gauge port. Not available with NEMA models.Accessories—order separatelyWMPSK Wall mount power supply kit, 115 VAC/12 VDCRB Protective rubber boot. Not avail. with NEMA models.CD Calibration data; 5 test points and dateNC NIST traceability documentation, 5 points and dateF16ADNpsi = PSIinHg = INHGoz/in2 = ZINinH2O = INH2OftH2O = FTH2OmmHg = MMHGtorr = TORRmmH2O = MMH2Okg/cm2 = KGCMg/cm2 = GCMkPa = KPAMPa = MPAmbar = MBARbar = BARcmH2O = CMH2Oatm = ATMG = gauge reference pressureVAC = gauge reference vacuumA = absolute referenceIf vacuum gauge requires a minus sign, please specify.The range code indicates the gauge’s default range. Engineeringunits may be changed to any of those listed under the same sensorrange. The listed ranges are rounded off.Range—see table at leftH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USASensor Ranges and Engineering Units ‡ -HA option not available. Consult factory for special units.3 psig ‡ Res 15 psig vac ‡ Res 30 psia Res –15V100psig ‡ Res 300 psig Res3PSIG .001 100KPAVAC .1 2KGCMA .001 –15V100PSIG .1 300PSIG .16INHGG .001 0.1MPAVAC .0001 2ATMA .001 –30INHG/100PSIG .1 610INHGG .185INH2OG .1 1BARVAC .001 30 psig Res –30V200INHGG .1 4800ZING 150ZING .01 1KGCMVAC .001 30PSIG .01 –400V2770INH2OG 1 700FTH2O .1210GCMG .1 1ATMVAC .001 60INHGG .01 –240V1600ZING 1 2000KPAG 1150MMHGG .1 15 psig Res 850INH2OG 1 –760V5200MMHGG 1 2MPAG .001150TORRG .1 15PSIG .01 480ZING .1 –760V5200TORRG 1 20BARG .01200MBARG .1 30INHGG .01 2100GCMG 1 –100V700KPAG 1 20KGCMG .01200CMH2OG .1 400INH2OG .1 1600MMHGG 1 –0.1V0.7MPAG .001 20ATMG .012000MMH2OG 1 240ZING .1 1600TORRG 1 –1V7BARG .01 500 psig Res7FTH2O .001 1000GCMG 1 2000MBARG 1 –1V7KGCMG .01 500PSIG .120KPAG .01 760MMHGG .1 2100CMH2OG 1 –1V7ATMG .01 1020INHGG 15 psig ‡ Res 760TORRG .1 70FTH2O .01 100 psig Res 1150FTH2O 15PSIG .001 1000MBARG 1 200KPAG .1 100PSIG .1 3500KPAG 110INHGG .01 1000CMH2OG 1 0.2MPAG .0001 200INHGG .1 3.5MPAG .001140INH2OG .1 35FTH2O .01 2BARG .001 2770INH2OG 1 35BARG .0180ZING .1 100KPAG .1 2KGCMG .001 1600ZING 1 35KGCMG .01350GCMG .1 0.1MPAG .0001 2ATMG .001 7000GCMG 1 35ATMG .01260MMHGG .1 1BARG .001 60 psig Res 5200MMHGG 1 1000 psig Res260TORRG .1 1KGCMG .001 60PSIG .01 5200TORRG 1 1000PSIG 1350MBARG .1 1ATMG .001 120INHGG .1 7000MBARG 1 2040INHGG 1350CMH2OG .1 ±15 psig ‡ Res 1660INH2OG 1 7000CMH2OG 1 2300FTH2O 13500MMH2OG 1 ±15PSIG .01 960ZING 1 230FTH2O .1 7000KPAG 112FTH2O .01 –30INHG/15PSIG .01 4200GCMG 1 700KPAG .1 7MPAG .00135KPAG .01 ±30INHGG .01 3100MMHGG 1 0.7MPAG .0001 70BARG .0115 psia Res ±400INH2OG 1 3100TORRG 1 7BARG .001 70KGCMG .0115PSIA .01 ±240ZING .1 4100MBARG 1 7KGCMG .001 70ATMG .0130INHGA .01 ±1000GCMG 1 4200CMH2OG 1 7ATMG .001 2000 psig Res400INH2OA .1 ±760MMHGG 1 140FTH2O .1 –15V200 psig ‡ Res 2000PSIG 1240ZINA .1 ±760TORRG 1 400KPAG .1 –15V200PSIG .1 4070INHGG 11000GCMA 1 ±1000MBARG 1 0.4MPAG .0001 –30INHG/200PSIG .1 4600FTH2O 1760MMHGA .1 ±1000CMH2OG 1 4BARG .001 –30V400INHGG .1 14MPAG .01760TORRA .1 ±100KPAG .1 4KGCMG .001 –400V5500INH2OG 1 140BARG .11000MBARA 1 ±0.1MPAG .0001 4ATMG .001 –240V3200ZING 1 140KGCMG .11000CMH2OA 1 ±1BARG .001 100 psia Res –100V1400KPAG 1 140ATMG .1100KPAA .1 ±1KGCMG .001 100PSIA .1 –0.1V1.4MPAG .001 3000 psig Res0.1MPAA .0001 ±1ATMG .001 200INHGA .1 –1V14BARG .01 3000PSIG 11BARA .001 30 psia Res 2770INH2OA 1 –1V14KGCMG .01 6100INHGG 11KGCMA .001 30PSIA .01 1600ZINA 1 –1V 14ATMG .01 6900FTH2O 11ATMA .001 60INHGA .01 7000GCMA 1 200 psig Res 20MPAG .0115 psig vac ‡ Res 850INH2OA 1 5200MMHGA 1 200PSIG .1 200BARG .115PSIVAC .01 480ZINA .1 5200TORRA 1 400INHGG .1 200KGCMG .130INHGVAC .01 2100GCMA 1 7000MBARA 1 5500INH2OG 1 200ATMG .1400INH2OVAC .1 1600MMHGA 1 7000CMH2OA 1 3200ZING 1 5000 psig Res240ZINVAC .1 1600TORRA 1 700KPAA .1 480FTH2O .1 5000PSIG 11000GCMVAC 1 2000MBARA 1 0.7MPAA .0001 1400KPAG 1 35MPAG .01760MMHGVAC .1 2100CMH2OA 1 7BARA .001 1.4MPAG .001 350BARG .1760TORRVAC .1 200KPAA .1 7KGCMA .001 14BARG .01 350KGCMG .11000MBARVAC 1 0.2MPAA .0001 7ATMA .001 14KGCMG .01 340ATMG .11000CMH2OVAC 1 2BARA .001 14ATMG .01Quick Linkcecomp.com/adNEMA 4XHousingSCR14SSFilter screen fitting keeps debris out of gaugesensor. Use for food vacuum packaging applica-tions. 303 SS body, 100 micron 304 SS screen.© 08-18cecomp.com1220 American Way Libertyville, IL 60048800-942-0315CECOMP Div. of ABSOLUTE PROCESS INSTRUMENTS |
Related manuals for Absolute Process Instruments Cecomp F16AD
Absolute Process Instruments Cecomp Test+ CTP3B Instructions Manual
Absolute Process Instruments Cecomp DPG2000B Series Instructions Manual
Absolute Process Instruments Cecomp F20B Quick Start Manual
Absolute Process Instruments APD 4008 Quick Start Manual
Absolute Process Instruments API 4008 G Quick Start Manual
Absolute Process Instruments API 4008 G Quick Start Manual
Absolute Process Instruments API 4003 G I Quick Start Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine