Cecomp® Test + Battery Powered Digital Pressure Gauges, User Configurable CTP3BRanges and ResolutionSee table below for rangesDefault engineering unit: psiUser configurable for other engineering unitsResolution is fixed for each engineering unitAccuracyAccuracy includes linearity, hysteresis, repeatabilitySensor hysteresis: ±0.015% FS, included in accuracySensor repeatability: ±0.01% FS, included in accuracyPressure and absolute ranges±0.1% full scale ±1 least significant digitVacuum and vacuum/pressure ranges±0.25% full scale ±1 least significant digitDisplay3 readings per second nominal display update rate4 digit LCD, 0.5"H and 5 character 0.25"H alphanumericWhite LED backlight active with button keypressBatteries, Battery Life, Low Battery Indication2 AA alkaline includedApprox. 150-1500 hours depending on backlight usageLow battery symbol on displayControls and FunctionsThree button keypadZero/clear/upOn/offMemory/downPasscode protected calibration, engineering unit selection, autoshutoff time, min/max setupMin/Max MemoryMinimum and/or maximum readings stored in memoryReadings cleared or stored at shutoffUser configurableCalibrationZero button for gauge reference rangesNon-interactive zero, span, and linearity, ±10% of rangeAuto ShutoffFactory default: 5 minutesUser selectable 1 minute to 8 hours or front button on/offWeightGauge: 9 ounces (approximately)Shipping: 1 pound (approximately)Housing MaterialsEpoxy powder coated aluminum case with case stiffener,ABS/ polycarbonate bezel, coated circuit boards for humidityresistance, front and rear rubber gaskets, polycarbonate labelNEMA 2Includes rubber bootConnection and Material1/4" NPT male fittingAll wetted parts are 316L stainless steelOverpressure, Burst, Vacuum Service3000 psig sensor: 5000 psig overpressure5000 psig sensor: 7500 psig overpressureAll others: 2 X pressure range overpressureBurst pressure: 4 X sensor pressure rating, or 10,000 psi,whichever is lessVacuum service: 15 psia, ±15 psig, 15 psig, 30 psia,100 psig, 100 psia, 200 psig sensorsEnvironmental TemperaturesStorage: –40 to 203°F (–40 to 95°C)Operating: –4 to 185°F (–20 to 85°C)Compensated range: 32 to 158°F (0 to 70°C)Dimensions3.67"W x 3.19"H x 2"D with boot, not including fitting© 10-19cecomp.com1220 American Way Libertyville, IL 60048800-942-0315CECOMP Div. of ABSOLUTE PROCESS INSTRUMENTScecomp.com/plusH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAPb LeadFreeO ±0.1% Test Gauge Accuracy in Most RangesO Ruggedized DesignO Red Rubber Boot IncludedO 316L Stainless Steel Wetted PartsO Selectable Units and Auto Shutoff TimesO White LED Display BacklightO Min/Max MemoryCON14SSQuick connector to install or remove gaugewithout tools. 304 stainless steel, urethaneseal.SCR14SSFilter screen fitting keeps debris out of gaugesensor. For food vacuum packaging applica-tions. 303SS body, 100 micron 304SS screen.Accessories—order separatelyDPG-OK2, DPG-OK3, DPG-OK6Pelican® brand high visibility orange heavyduty waterproof cases. Models available forstoring 2, 3, or 6 gauges.Vacuum Range/Resolution Accuracy Selectable UnitsCTP3B15PSIVAC 0 to 14.70 psig vacuum ±0.25% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2 cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaVacuum/Pressure Range/Resolution Accuracy Selectable UnitsCTP3B±15PSIG –14.7 to 15.0 psig ±0.25% FS ±1 LSD psi, inHg/psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B15V100PSIG –14.7 to 100.0 psig ±0.25% FS ±1 LSD psi, inHg/psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, MPa, kPaCTP3B15V200PSIG –14.7 to 200.0 psig ±0.25% FS ±1 LSD psi, inHg/psi, inHg, torr inH2O, ftH2O, oz/in2, kg/cm2, atm, bar, MPa, kPaPressure Range/Resolution Accuracy Selectable UnitsCTP3B3PSIG 0 to 3.000 psig ±0.25% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, mmH2O, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, kPaCTP3B5PSIG 0 to 5.000 psig ±0.25% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, mmH2O, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, kPaCTP3B15PSIG 0 to 15.00 psig ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B30PSIG 0 to 30.00 psig ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B60PSIG 0 to 60.00 psig ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B100PSIG 0 to 100.0 psig ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B200PSIG 0 to 200.0 psig ±0.1% FS ±1 LSD psi, inHg, inH2O, ftH2O, oz/in2, kg/cm2, atm, bar, MPa, kPaCTP3B300PSIG 0 to 300.0 psig ±0.1% FS ±1 LSD psi, inHg, ftH2O, oz/in2, kg/cm2, atm, bar, MPa, kPaCTP3B500PSIG 0 to 500.0 psig ±0.1% FS ±1 LSD psi, inHg, ftH2O, kg/cm2, atm, bar, MPa, kPaCTP3B1000PSIG 0 to 1000 psig ±0.1% FS ±1 LSD psi, inHg, ftH2O, kg/cm2, atm, bar, MPa, kPaCTP3B2000PSIG 0 to 2000 psig ±0.1% FS ±1 LSD psi, inHg, ftH2O, kg/cm2, atm, bar, MPaCTP3B3000PSIG 0 to 3000 psig ±0.1% FS ±1 LSD psi, inHg, ftH2O, kg/cm2, atm, bar, MpaCTP3B5000PSIG 0 to 5000 psig ±0.1% FS ±1 LSD psi, kg/cm2, atm, bar, MpaAbsolute Reference Range/Resolution Accuracy Selectable UnitsCTP3B15PSIA 15.00 to 0 psi absolute ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B30PSIA 30.00 to 0 psi absolute ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCTP3B100PSIA 100.0 to 0 psi absolute ±0.1% FS ±1 LSD psi, inHg, torr, mmHg, inH2O, ftH2O, oz/in2, cmH2O, g/cm2, kg/cm2, atm, bar, mbar, MPa, kPaCalibration Documentation Options—add to end of model numberCD Calibration data; 5 test points and date NC NIST traceability documentation, 5 points and date