Absolute Process Instruments IsoSplitter APD 6393 Quick Start Manual
IsoSplitter® AC to DC Signal Splitter/Isolator/Transmitter, Factory Configured APD 63931 Input: True RMS 0-50 mVAC to 0-300 VAC, 0-1 mAAC to 0-1000 mAAC2 Outputs: 0-1 V to 0-10 V, ±1 V to ±10 V, 0-1 mA to 20 mA, 4-20 mAO One Input to Two Outputs with Full IsolationO Zero and Span Output Calibration PotentiometersO Full 1200 V Input/Output /Power IsolationO Input and Output LoopTracker®LEDsO Output Test Button for Each ChannelO Built-In Loop Power Supplies for Sink/Source I/OQ Split, Convert, Boost, and Rescale Process SignalsQ Split Process Signals for Control and ValidationQ Interface a Process Signal with Multiple Panel Meters,PLCs, Recorders, Data Acq., DCS, & SCADA SystemsApplicationsOptions—add to end of model numberR1 Channel 1 I/O reversal (ie. 4-20 mA in to 20-4 mA out)R2 Channel 2 I/O reversal (ie. 4-20 mA in to 20-4 mA out)R3 Channel 1 and channel 2 I/O reversalM19 Channel 1 high voltage output >10 V up to 20 VM29 Channel 2 high voltage output >10 V up to 20 VM39 Channel 1 and channel 2 high voltage outputU Conformal coating for moisture resistanceAccessory—order as separate line itemAPI BP4 Spare removable 4 terminal plug, blackDescriptionThe APD 6393 IsoSplitter accepts an AC voltage or currentinput and provides two optically isolated DC voltage or currentoutputs that are linearly related to the input. The input rangeand each output range are independent and can be specified asrequired. This provides an economical solution when one signalmust be sent to two different devices.Typical applications include isolation, output splitting, outputdevice separation and redundancy (i.e. to prevent failure ofthe entire loop if one device fails), or a combination of these.The input signal is filtered, amplified, split, and then passedthrough an opto-coupler to the output stages. Full 4-way isola-tion (input, output 1, output 2, power) make this module usefulfor ground loop elimination, common mode signal rejection,and noise pickup reduction.I/O Sink/Source VersatilityStandard on the APD 6393 is a 15 VDC sensor excitation supplyfor the input channel and 20 VDC loop excitation supplies foreach output channel. These power supplies can be selectivelywired for sinking or sourcing allowing use with any combina-tion of powered or unpowered milliamp I/O devices.LoopTrackerAPI exclusive features include three LoopTracker LEDs (greenfor input, red for each output) that vary in intensity withchanges in the process input and output signals.These provide a quick visual picture of your process loop at alltimes and can greatly aid in saving time during initial startupand troubleshooting.Output TestAn API exclusive feature includes output test buttons for eachchannel to provide a fixed output (independent of the input)when held depressed. A test button is provide for each outputchannel. The output test greatly aids in saving time duringinitial startup and/or troubleshooting.The test output level for each channel is potentiometer adjust-able from 0 to 100% of the output span.Terminals are provided to operate the test functions remotelyfor each channel. This also allows use as a remote manualoverride to provide a temporary fixed output if desired.AC Input RangeFactory configured, please specify input type and rangeVoltage: 0-50 mVAC to 0-300 VACCurrent: 0-1 mAAC to 0-1000 mAACMeasurements are true RMSInput Frequency40 Hz to 1000 Hz sinusoidalInput Impedance (Voltage Input)220 kΩ minimumInput Voltage Burden (Current Input)1.0 VRMS maximumInput Protection, Common Mode750 VDC or 750 VACpLoopTrackerVariable brightness LEDs indicate I/O loop level and statusOne for input, one for each outputChannel 1 and Channel 2 DC Output RangesFactory configured, please specify for each output channelVoltage: 0-1 VDC to 0-10 VDC, 10 mA maxup to 20 VDC with M19, M29, M39Bipolar voltage: ±1 VDC to ±10 VDCCurrent: 0-1 mADC to 0-25 mADC, 4-20 mADC20 V compliance, 1000 Ω at 20 mAOutput CalibrationMulti-turn zero and span potentiometers for each output channel±15% of span adjustment range typicalOutput Loop Power Supplies20 VDC nominal, regulated, 25 mADC for each output channelMay be selectively wired for sinking or sourcing mA outputOutput Test/OverrideFront momentary buttons or external contact closures foreach channel to set output test levels.Each output test level potentiometer adjustable 0-100% of spanOutput Ripple and NoiseLess than 10 mVRMSLinearityBetter than ±0.1% of spanAmbient Temperature Range and Stability–10°C to +60°C operating ambientBetter than ±0.04% of span per °C stabilityResponse Time70 milliseconds nominalIsolationFull 4-way, 1200 VRMS minimumInstallation EnvironmentIP 40, requires installation in panel or enclosure with ade-quate ventilationFor use in Pollution Degree 2 EnvironmentMount vertically (as shown in picture) to a 35 mm DIN railallowing minimum 1" (25 mm) above and below housingvents for air circulation.Power85-265 VAC, 50/60 Hz or 60-300 VDC, 6 W maximumD versions: 9-30 VDC or 10-32 VAC 50/60 Hz, 6 W maximumDimensions and Connectors1.78" W x 4.62" H x 4.81" D45 mm W x 117 mm H x 122 mm DEight 4-terminal removable connectors, 14 AWG max wire sizeHow to OrderModels are factory ranged. See I/O ranges above left.Please specify ranges and options on orderInput rangeChannel 1 output rangeChannel 2 output rangeSee options at rightModel Description PowerAPD 6393 IsoSplitter1 input to2 outputs85-265 VAC, 50/60 Hz or60-300 VDCAPD 6393 D 9-30 VDC or 10-32 VACOptions and Accessories© 11-19api-usa.com1220 American Way Libertyville, IL 60048Phone: 800-942-0315 Fax: 800-949-7502AABSOLUTEBSOLUTE PPROCESSROCESS IINSTRUMENTSNSTRUMENTSQuick Link: api-usa.com/6393Removable PlugsSink or SourcemA Output forEach ChannelOutput LoopTrackerLED for EachChannelInput LoopTrackerLEDZero and Span forEach ChannelConnect Sink orSource mA InputCustom I/O RangesAdjustable OutputTest Function forEach Channel1 2 3 4 5 6 7 89 10 11 12 13 14 15 1625 26 27 28 29 30 31 3217 18 19 20 21 22 23 24See WiringDiagrams onNext PageUniversal PowerFree FactoryI/O Setup!H H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HH H H H HH H H H H HMade in USAFile E14596885-265 VAC, 60-300 VDCmodel onlyApplications Linkapi-usa.com/appsPb LeadFree |
Related manuals for Absolute Process Instruments IsoSplitter APD 6393
Absolute Process Instruments IsoSplitter APD 1393 Quick Start Manual
Absolute Process Instruments IsoSplitter APD 3393 Quick Start Manual
Absolute Process Instruments IsoSplitter APD 7393 Quick Start Manual
Absolute Process Instruments IsoSplitter APD 4930 Quick Start Manual
Absolute Process Instruments APD 41393 Quick Start Manual
Absolute Process Instruments APD 41391 Quick Start Manual
Absolute Process Instruments DuoPak APD 2036 Quick Start Manual
Absolute Process Instruments DuoPak APD 2000 Series Quick Start Manual
Absolute Process Instruments DuoPak APD 2000 Series Quick Start Manual
Absolute Process Instruments DuoPak APD 2050 Manual
This manual is suitable for:
manualsdatabase
Your AI-powered manual search engine