Contents - Declaration of conformity
- Table Of Contents
- Table Of Contents
- Table Of Contents
- Quickstart guide
- Safety information
- Power supply
- Wireless operation
- Device overview
- International key assignment
- Device rear (mounting plate)
- Introduction
- Mounting/Installation
- Fixing the mounting plate to the wall
- Connecting the components
- Commissioning
- For a system that is already installed
- Configuration
- Menu control elements
- Login screen
- Main menu
- INFO
- Communication
- Status
- Components
- Detectors
- Wireless control panel
- External Sirens
- Info module/indoor siren
- WUM (Wireless Universal Module)
- Door locks
- RF repeater
- Outputs
- Wired Outputs
- Partitions
- Configure partitions
- System
- Installer details
- User access
- User reset
- Confirmation
- Hardware
- Security settings
- Backup/restore
- Panel upgrade
- Email setup
- VoIP dialler setup
- ARC reporting
- ARC Reporting, Phone Book
- ARC Reporting, Account Numbers
- ARC Reporting, Fast Fmt Channels (for "Fast Format" protocol only)
- ARC Reporting, CID/SIA Triggers (for all protocols EXCEPT "Fast Format")
- ARC Reporting, More
- Nursing emergency call
- Social Care, Phone Book
- Social Care, Account Numbers
- Voice dialler
- Speech Dialler, Triggers
- Speech Dialler, Destinations
- SMS, Triggers
- SMS, Destinations
- SMS, Destinations, Message
- SMS, Destinations, Message, Telephone Recipients
- SMS, Messages
- SMS, PSTN SMS
- Email
- Email, Triggers
- Email, Destinations
- Email, Messages
- Communication options
- Contacts
- Test
- Virtual keypad
- Appendix
- Compatible equipment
- Default values/factory defaults
- User menu
- Repairs and maintenance
- S/W upgrade
- ARC/ESCC reporting
- CID/SIA Events
- Email error messages
- TCP/IP error messages
- VoIP error messages
- Log book entries
- User numbers
- Troubleshooting
- Carry out a GSM manual test call, prepaid
- Trace, recording communication sequences
- Time zones
- GSM network notification centre
- Email notification/email setup
- Index
- Linker Kreuthweg
|
Configuration56WUM (Wireless Universal Module)Name/function ExplanationNumber The number comprises the component type (WAM) and a consecutive number.Name Unique name of the wireless universal moduleAdding a wireless universal module.NoteEnsure that reserved outputs and zones areassigned to each WAM.See the table of reserved WAM outputs/zonesbelow.WirelessuniversalmoduleReservedoutputsReservedzonesWAM 1 229–232 248WAM 2 225–228 247WAM 3 221 – 224 246WAM 4 217–220 245WAM 5 213–216 244WAM 6 209–212 243WAM 7 205–208 242WAM 8 201–204 241NoteConfigure the universal module as describe in theWUM installation instructions, e.g. as a wirelesssender/receiver (function 3).Once the wireless universal module has beenconfigured as per the instructions, it can be addedto the system.1. Select Add/Del WAM.2. Select the corresponding wireless universal module(WAM). Up to eight wireless universal modulescan be taught in.3. Select, for example, WAM 1.4. Trigger the tamper contact on the WAM.NoteWhen WAM modules are taught in, the symbolappears next to the WAM number.Check the information of the wireless universalmodule.5. Select WAM Info.
PreviousNext |