Copyright © Access-IS 2015Page 20 of 396. Barcode Engine/Imager Command ReferenceCommands are sent with a prefix of [0x16][0x4D][0x0D] causing the command sequence to take theform [0x16][0x4D][0x0D]parameter (if required).The command is concluded by a dot ‘.’ or an exclamation mark ‘!’. The dot stores the settingpermanently and the exclamation mark keeps it temporarily until power is removed from the device.To query the current settings, send the six character Command with a “?” instead of the parameterand the ATR will return the Command with the current setting.To query the permanently stored settings, send the six character Command with a “^” instead of theparameter and the ATR will return the Command with the stored setting.To access the help string, send the six character Command with a “*” instead of the parameter andthe ATR will return the Command with the parameter options.6.1 Basic ConfigurationCommand Description Default Parameters/RangeAISINF Select the interface.When a serial cable is used theconfiguration will be overruled andAISINF0 is used.When a USB cable is used theconfiguration AISINF0 will be overruledto AISINF1.1 0 - Serial1 - USB CDC2 - USB keyboard3 - HID POSAISBAU Set baud rate of serial connection.Only used when AISINF above is set to0 (Serial).9 0 - 300 bps1 - 600 bps2 - 1200 bps3 - 2400 bps4 - 4800 bps5 - 9600 bps6 - 19200 bps7 - 38400 bps8 - 57600 bps9 - 115200 bpsAISSCP Set connection parameters of serialconnection.Only used when AISINF is set to 0(Serial).2 0 - 7N11 - 7N22 - 8N13 - 7E14 - 7E25 - 8E16 - 7O17 - 7O28 - 8O1AISKBL Keyboard localization; this defines theWindows keyboard mapping for correctoutput of characters.Only used when AISINF is set to 2 (USBKeyboard).0 0 - US1 - UK2 - IT (Italy)3 - ES (Spanish)4 - DE (German)5 - CH