ENWMBUS ANALOG PWR - Guide utilisateur / User guide version V2.0.172Page of 83FR5. PREPARATION AND CONFIGURATIONS5.1. Disassembling the casingThe product is delivered disassembled so that you can access the lower part of the electronics. This part enables the sensor or sensors to beconnected to the screw terminals as well as access to the configuration switches.Once assembly of the sensors has been finalized and the configuration has been carried out, the casing can be closed.NB: Once the casing is closed, it will no longer be possible to open it without running the risk of voiding the IP67 protection index guarantee.5.2. Fitting the packing gland sealBefore connecting your sensor’s cable strands to the product’s screw terminals, you must insert the packing gland’s nut and the seal appropriatefor your configuration.Three types of seals are supplied with product: For a cable with a diameter of 5 mm, for a cable with a diameter of 3 mm, and for two cableswith diameters of 2.2 mm.Assembly procedure:5.3. Mounting the sensor on the screw terminalsOnce the nut and the packing gland seal are fitted, the sensor cables’ strands can be connected to the product unit’s screw terminals.10590 2750Note: A maximum of 2 sensors may be used in parallel. The user can choose freely between analog and digital optionsAnalog sensors require an electric power supply. The power supply of the sensor may be the same as that of the WMBUS ANALOG PWR, provid-ed that the supply voltage is compatible with both.Below is an installation recommendation that will ensure smooth running of the adeunis® product + 0-10V sensor assemblySeal for 1 x 5 mm diam. cable Seal for 1 x 3 mm diam. cable Seal for 2 x 2.2 mm diam. cables1 - Your sensor andits cable2 -Pass the cablethrough the packinggland nut3 - Pass the cablethrough the packinggland seal6 - Connect the sen-sor cable strands tothe screw terminals4 - Pass the cablethrough the sensorcasing base5 - Fit the O-ringonto the seal of thecasing base