ENsigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.061Page of 99FR2.1.4 DEAD modeThe product enters this very low consumption mode following the detection of a level of battery that is too low. In this mode the product wakesup every 5 seconds to make the red LED flash twice.The replacement of the battery (if the product is a replaceable battery version) followed by the application of the magnet takes the product outof this mode to return it to the operating mode.2.2. Application operation2.2.1 Periodic transmissionThe product allows the measurement and the periodic transmission of the values of the sensors according to the following diagram:Product in standbySend frame 0x46Periodreached?YesNoDetectedand valida-ted pulse?Countingof the impulseYesNoThe settings associated with this mode of operation are:• Transmission period (register 301)• Enabling and Configuring inputs (register 320)• Debounce timer period (registers S322)A complete list of the registers can be found in paragraph 3.4.Eg:Registre Value encoding Value ResultS301 Decimal 6 Periodic mode with a period of 6x10min = 60 minutesS320 Hexadecimal 0x39 Channel A :• Activated• Meter other than gas• Tamper input activatedChannel B :• Activated• Gas meter• Tamper input disabledS322 Hexadecimal 0x57 Debounce :• Channel A = 500ms• Channel B = 100ms