ENsigfox RC2 Pulse - Guide utilisateur / User guide version V1.0.080Page of 99FR4.1.7 Alarm frameThis frame (0x47) is sent if the measured flow of one of the channels exceeds the configured threshold for this channel (registers S326 and S327).0 1 2 to 3 4 to 5Code Status PAYLOAD0x47 Cf Status Measured flow - channel A Measured flow - channel B0x47 0xA3 0x2904 0x206CIts size is of 6 bytes.Description of the frame :• Bytes 2 to 3: measured flow on channel A when detecting the exceeding of flow, in pulses per hour.• Bytes 4 to 5: measured flow on channel B when detecting the exceeding of flow, in pulses per hour.In the example in grey this gives:• Bytes 2 to 3: measured flow on channel A when detecting the exceeding of flow, in pulses per hour = 0x2904 so 10,500 pulses per hour• Bytes 4 to 5: measured flow on channel B when detecting the exceeding of flow, in pulses per hour = 0x206C so 8,300 pulses per hour4.1.8 Periodic frame with 1 hour-historyThis frame (0x48) is sent every hour if the feature is activated in register S321.Frame 1/4 :0 1 2 3 to 6 7 to 10Code Status PAYLOAD…0x48 Cf Status Frame index Counter - channel A Counter - channel B0x48 0xA3 0 0x00015C4F 0x0000F74ADescription of the frame :• Byte 2: frame index: index of this frame in a multi-message sequence (always null in this configuration).• Bytes 3 to 6 : Counter - channel A : counter value of channel A 10 minutes after transmitting the previous frame.• Bytes 7 to 10 : Counter - channel B : counter value of channel B 10 minutes after transmitting the previous frame.In the example in grey this gives:• Byte 2: frame index: index of this frame in a multi-message sequence (always null in this configuration) = 0 (first frame)• Bytes 3 to 6 : Counter - channel A : counter value of channel A 10 minutes after transmitting the previous frame = 0x00015C4F so 89,167 pulses• Bytes 7 to 10 : Counter - channel B : counter value of channel B 10 minutes after transmitting the previous frame = 0x0000F74A so63,306 pulsesFrame 2/4 :0 1 2 3 to 4 5 to 6 7 to 8 9 to 10Code Status PAYLOAD…0x48 Cf Status Frame index Delta A0 Delta B0 Delta A1 Delta B10x48 0xA3 1 0x0012 0x0020 0x0007 0x0010Description of the frame:• Byte 2: frame index: index of this frame in a multi-message sequence• Bytes 3 to 4 : Delta A0 : index variation of channel A during the time interval between 10 to 20 minutes after transmitting the previousframe.• Bytes 5 to 6 : Delta B0 : index variation of channel B during the time interval between 10 to 20 minutes after transmitting the previousframe.• Bytes 7 to 8 : Delta A1 : index variation of channel A during the time interval between 20 to 30 minutes after transmitting the previousframe.• Bytes 9 to 10 : Delta B1 : index variation of channel B during the time interval between 20 to 30 minutes after transmitting the previousframe.