28 User’s GuideElectromagnetic CompatibilityLike other electrical medical equipment, the AMM213TD/AMM240WTD requires specialprecautions to ensure electromagnetic compatibility with other electrical medical devices. Toensure electromagnetic compatibility (EMC), the AMM213TD/AMM240WTD must be installedand operated according to the EMC information provided in this manual.Note The AMM213TD/AMM240WTD has been designed and tested to comply withIEC 60601-1-2:2001 requirements for EMC with other devices.Caution Portable and mobile RF communications equipment may affectthe normal function of the AMM213TD/ AMM240WTD.Warning Do not use cables or accessories other than those providedwith the AMM213TD/AMM240WTD, as this may result in increased electromag-netic emissions or decreased immunity to such emissions.Warning If the AMM213TD/AMM240WTD is used adjacent to or stackedwith other equipment, observe and verify normal operation of the AMM213TD/AMM240WTD in the configuration in which it will be used prior to using it in asurgical procedure. Consult the tables below for guidance in placing the AM-The Model AMM213TD/AMM240WTD is intended for use in the electromagnetic environment specified below.The customer or the user of AMM213TD/AMM240WTD should assure that it is used in such an environment.Emission test Compliance Electromagnetic environment - guidanceRF emissions CISPR 11 Group 1The Model AMM213TD/AMM240WTD uses RF energy only forits internal function. Therefore, its RF emissions are very lowand are not likely to cause any interference in nearby electronicequipmentRF emissions CISPR 11 Class BAMM213TD/AMM240WTD is suitable for use in allestablishments, including domestic establishments and thosedirectly connected to the public low-voltage power supplynetwork that supplies buildings used for domestic purposesHarmonic emissionsIEC61000-3-2 Class DVoltage FluctuationsIEC61000-3-3 CompliesManufacturer’s declaration - electromagnetic emissionThe Model AMM213TD/AMM240WTD is intended for use in the electromagnetic environment specified below.The customer or the user of AMM213TD/AMM240WTD should assure that it is used in such an environment.Immunity Test IEC 60601 Test Level Compliance Level Electromagneticenvironment - guidanceElectrostatic discharge(ESD)IEC61000-4-26 kV contact8 kV air6 kV contact8 kV airFloors should be wood,concrete or ceramic tile.If floors are covered withsynthetic material, the relativehumidity should be at least30%.Electrical fast transient/burst IEC61000-4-42 kV for power supply lines1 kV for input / output lines2 kV for power supply lines1 kV for input / output linesMains power qualityshould be that of a typicalcommercial or hospitalenvironment.SurgeIEC61000-4-51 kV differential mode2 kV common mode1 kV differential mode2 kV common modeMains power qualityshould be that of a typicalcommercial or hospitalenvironment.Manufacturer’s declaration - electromagnetic immunity