POWER MANAGEMENT FUNCTIONThe monitor is equipped with the power management function which automatically reducethe power consumption when not in use in three power level modes.• Stand-by ModeThe monitor goes into stand-by mode when the horizontal sync signal is off forabout 10 seconds. In this mode, the screen goes off and the power LED blinks for 1seconds On and 1 second Off. The screen is displayed after the horizontal syncsignal is restored.• Suspend ModeThe monitor goes into suspend mode when the vertical sync signal is off for about10 seconds. The power consumption during this is less than 8 W. In this mode, thescreen goes off and the power LED blinks for 1 seconds On and 1 second Off. Thescreen is displayed after the vertical sync signal is restored.• Off ModeThe monitor goes into power-off mode when the vertical and horizontal sync signalsare off for about 10 seconds. In this mode, the screen goes off and the power LEDblinks for 1 seconds On and 1 second Off. The screen is displayed after the verticaland horizontal sync signals are restored.Power Management SystemThe AMM240WTD Medical Monitor power management proposal. Provides fourphases of power-saving modes by detecting the horizontal sync signal as shown inthe table below.When the monitor is power saving mode or detects an incorrect timing, the screen willbe blank and power LED indicator will blink.10 User’s Guide27W27W27W97WPowerConsumptionRed Flashing(1 sec.Interval)Red Flashing(1 sec. Interval)Red Flashing(1 sec. Interval)GreenPower IndicatorBlankedBlankedBlankedActiveVideoInactiveInactiveActiveActiveVertical SyncInactiveActiveInactiveActiveHorizontal SyncDPMS OffDPMS suspendDPMS StandbyNormalOperationState27W27W27W97WPowerConsumptionRed Flashing(1 sec.Interval)Red Flashing(1 sec. Interval)Red Flashing(1 sec. Interval)GreenPower IndicatorBlankedBlankedBlankedActiveVideoInactiveInactiveActiveActiveVertical SyncInactiveActiveInactiveActiveHorizontal SyncDPMS OffDPMS suspendDPMS StandbyNormalOperationState