Mechanical installationDLT-V72 Operating Instructions V2.50 85 / 12112.3. Mounting the DLT-V72 at the deployment locationWARNINGRisk of injury and damage due to improper deployment location. Observe the intended use of the DLT-V72, e.g. not in potentially explosive areas, not in life-supportingfacilities. Ensure that the deployment location of the DLT-V72 complies with the permissible environmentalconditions. The installation height of the device shall not exceed 2 m.Risk of accident on vehicles due to unstable attachment of the DLT-V72. When installing the DLT-V72, make sure that if the bracket breaks (e.g. because of a stress fracture)no one will be injured. Alternatively please put appropriate safety measures in place (e.g. install a security cable in addition tothe mounting bracket).Radio wave emission in the vicinity of persons.To ensure that the limits set for exposure to radio waves are not exceeded: Install the DLT-V72 so that persons maintain a minimum distance of 20 to 50 cm to the antenna.NOTICE: Property damageInstallation environment without cooling air can overheat / damage the DLT-V72.The DLT-V72 employs a passive cooling concept whereby the waste heat generated inside the device isemitted from the surface of the housing. For this system to function properly, sufficient fresh air circulationis required. If there is no access to fresh cooling air, it may result in overheating and severe damage to thedevice.Never install the system in a closed environment where the cooling air is unable to dissipate accumulatedheat to the outside.The maximum permissible ambient temperature for the entire system needs to be taken into account for thespecific application area.