Page 14 AXIS 211M Installation GuideResetting to the Factory Default SettingsThis will reset all parameters, including the IP address, to the Factory Default settings:1. Disconnect power from the camera.2. Press and hold the Control button for 15 seconds and reconnect power.3. Keep the button pressed until the Status Indicator displays amber (this may take up to15 seconds), then release button.4. When the status indicator displays green (which can take up to 1 minute) the camera isreset to the factory default settings.5. Re-assign the IP address, using one of the methods described in this document.It is also possible to reset parameters to the original factory default settings via the webinterface. For more information, please see the online help or the user’s manual.Further informationThe user’s manual is available from the Axis Web site at www.axis.com or from the AxisNetwork Video Product CD supplied with this product.Tip!Visit www.axis.com/techsup to check if there is updated firmware available for yourAXIS 211M. To see the currently installed firmware version, see the BasicConfiguration web page in the product’s Setup tools.