AXIS 211M - System Options36AdvancedScripting is an advanced function that provides the means for customizing and using scripts.Caution!The scripting function is a very powerful tool. Improper use may cause unexpected behavior or even loss ofcontact with the unit. If a script does cause problems, reset the unit to its factory default settings (in which case,a previously saved backup file will be useful for returning the unit to its latest configuration). Axis stronglyrecommends that you do not use this function unless you fully understand the consequences. Axis supportprovides no assistance for customized scripts.For more information, please visit the Developer pages at www.axis.com/developerPlain Config - this function is for the advanced user with previous experience of configuring Axis cameras. Allparameters can be set and modified from this page. Help is available via the links on the standard setup pages.Resetting to the Factory Default SettingsTo reset the camera to the original factory default settings, go to the System Options > Maintenance web page(as described in Maintenance, on page 35) or use the Control button on the rear of the camera (see theillustration on page 5) as described below:Using the Reset ButtonTo reset the camera to the factory default settings using the Reset Button:1. Disconnect the power adapter, or the network cable if using PoE.2. Press and hold the Reset button while reconnecting power.3. Keep the Reset button pressed until the Status Indicator color changes to amber (which may take up to15 seconds).4. Release the Reset button.5. When the Status Indicator changes to Green (which may take up to 1 minute), the process is completeand the camera has been reset. The unit will now have the default IP address 192.168.0.90