The Test Button54 AXIS OfficeBasic User’s ManualSection 9 The Test ButtonThe test button is located on the front right hand side of the print serverand is used for:• Printing a test page to check the connection to the printer.• Printing a server report and parameter list.• Performing a Factory Default of the print server.To change any of the parameters, use one of the methods described in“Print Server Management Methods” on page 39.The Test Page Press the test button once to print a test page. The test page containsbasic information about the print server. It is recommended that you printa test page when you connect the print server to a printer.Printing the ServerReport & ParameterListPress the test button twice to print a server report and parameter listshowing the current AXIS OfficeBasic settings.Server Report The Server Report includes the settings of the Axis Network Print Server,information about your connected printers as well as the current networksettings.Parameter List This list provides comprehensive details of all the parameters and theircurrent status. Refer to “The Parameter List” on page 58 for details.Performing a FactoryDefaultFollow the instructions below to restore the factory default values:1. Remove the external power supply to switch off the print server.2. Press and hold down the test button while you reconnect the external powersupply.3. Continue to hold down the test button until the network indicator remainsconstantly lit. This should take about 20 seconds.4. Restart the print server by disconnecting and reconnecting the externalpower supply.Important:A factory default will reset all print server parameters and settings to their default values.