AXIS A1214 Network Door Controller Kit- Supervised inputs were not evaluated by UL for burglar use.• System considerations- Monitoring software was not evaluated by UL, and is for supplemental use.• Maintenance instructions- For maintenance instructions and for information about how to configure theAxis product, see the User Manual.• Further information- Card formats verified by UL: ISO Cards Mifare 1K, 32 bits.• Power- Power in: 12 V DC, max 36 W. Power over Ethernet (PoE) IEEE 802.3at,Type 2 Class 4- Relay: 1x relay NO/NC, max 2 A DC- Power out lock: 19.2 W if powered by DC, 10.8 W if powered by PoE Class 4- Power out reader: 12 V DC, max 6 W- Auxiliary DC output: 1x 12 V DC output, max 200 mA- Total power budget for peripheral devices (locks, readers etc.): 2100 mA at12 V if powered by DC, 1400 mA at 12 V if powered by PoE Class 4• I/O interface – I/O functionality- Reader I/O: 12 V, max 500 mA- Reader data: OSDP/RS485 half duplex, Wiegand- Auxiliary:DC output: 12 V, 50 mAI/O: Two ports: configurable inputs or outputs- External: External tamper supervised input, alarm supervised input• Cable requirements- Wire size for connectors: CSA: AWG 28–16, CUL/UL: AWG 30–14- DC power and relay: AWG 18-16- Ethernet and PoE: STP CAT 5e or higher- Reader data (RS485): 1 twisted pair with shield, qualified for up to1000 m (3281 ft)- Reader data (Wiegand): Qualified for up to 150 m (500 ft)- Reader powered by controller (RS485): AWG 20-16, qualified for up to200 m (656 ft) (Depending on the reader’s voltage and current input range.Evaluated with A4020-E and A4120-E.)- Reader powered by controller (Wiegand): AWG 20-16, qualified for up to150 m (500 ft) (Depending on the reader’s voltage and current input range.)- I/Os as inputs: Qualified for up to 200 m (656 ft)7