USER MANUAL 35_________________________________________________________________________________________________________________17.4 Serial port parameters setting (SErIAL)The function allows setting independentlycommunication parameters of both of serial portsPort-1 and Port-2 (executed in RS232C, RS485,USB or LAN standard):- transfer protocol (Prot):LonG – cooperation with printer or computer,EPL – cooperation with label printer in normal mode(activates LAbEL function),EPL_A – cooperation with label printer in automaticmode (activates LAbEL function),EPL_d – cooperation with special label printers,Pen-01 – cooperation with PEN-01,- baud rate (bAud): (4800, 9600, ….115 200bps),- number of bits in single char. (bitS): 7, 8,- parity control (PArItY):nonE – no controlOdd –nonparityEven – parity control,- scale number in network (nr):(if the scale doesn’t work in network the numbermust be 0),- transmission through serial interface (SendInG):StAb – transmission after key is used andresult is stable,noStAb – transmission after key is pressedwithout need of stabilisation,Auto - automatic transmission after load is put onand result is stable (Auto),Cont - continuous transmission, about 10 resultsper second (Cont.),Remove - transDefault parameter values:Long, 9600 bps, 8 bits, none, StAb,- SCAnn – cooperation with MJ-4209 barcodereaders.In order to set needed parameters choose SErIAL function, select appropriate parameter and pressTkey when required option or parameter value is displayed.In scales with an additional serial port appear Port-1 and Port-2, for the independent setting of both ports.