AXIS P3346-VE Fixed Dome Network CameraHardware overviewFunction Pin Notes SpecificationsGND 1 Ground3.3 V DC Power 2 Can be used to power auxiliary equipment.Note: This pin can only be used as power out.Max load = 50 mADigital Input 3 Connect to GND to activate, or leave floating (unconnected)to deactivate.0 to +40 V DCDigital Output 4 Internal connection to ground when activated, floating(unconnected) when deactivated. If used with an inductiveload, e.g. a relay, a diode must be connected in parallel withthe load, for protection against voltage transients.Max load =100 mAMax voltage = +40 V DC3.3 V max 50 mA1234LED indicatorsLED Color IndicationGreen Steady for connection to a 100 MBit/s network. Flashes for network activity.Amber Steady for connection to a 10 MBit/s network. Flashes for network activity.NetworkUnlit No network connection.Green Steady green for normal operation.Amber Steady during startup and when restoring settings.StatusRed Slow flash for failed upgrade.Green Normal operation.PowerAmber Flashes green/amber during firmware upgrade.7