AXIS T8341 PIR Motion SensorHow to test the Z-Wave deviceHow to test the Z-Wave deviceWarm-upIt will take the motion sensor approximately 2 minutes to warm up after the battery is inserted. During this period the LED behind thelens will turn on. When the red LED turns off, the warm-up procedure is complete and the device is ready to detect.• This will not affect the Inclusion/Exclusion process.• After you remove the battery, wait 5 seconds before you refit it.Quick test1. If the tamper switch is not pressed after inclusion, the device will enter “Test mode”, to allow you to test the devicebefore it is mounted on the wall.2. If movement is detected during “Test mode”, the LED on the motion sensor will light up once, indicating that the unit isworking properly. The re-trigger time is about 5 seconds.3. To exit “Test mode” and enter normal mode, press the tamper switch for more than 10 seconds.4. When the PIR is triggered during normal mode, the red LED will not light up, and re-trigger time is based on a set value.NoteImportant! Make sure you create a Z-Wave controller event that is linked to the battery status signal. In this way you willget a notification or a LED indication when a device starts to experience low battery power.6