Multi-Zone Gas Monitors12 P/N: 3015-5074 Rev 112.2.6. Installing an Optional Splitter KitSplitter kits are made available which allow the MZ unit to take gas sample readings from several samplepoints while utilizing just a single zone. These kits are designed for use ONLY in confined/defined spaceswith high potential for leaks, such as food cases, cold rooms, refrigeration rack rooms, etc. Bacharach’s2-way (P/N 3015-5404) and 3-way (P/N 3015-5405) splitter kits are available as optional accessories. Referto instruction 3015-5415 (supplied with the kit) for detailed installation instruction.2.2.7. Connecting the Water TrapThe water trap is an optional accessory for applications that result in water or condensation frequentlyentering the intake lines. This is available in a manual style trap (P/N 0007-1655) which is manuallyemptied once it has become filled. Install the water trap close to the unit for the most effective results. Theintake line may be cut where the user finds appropriate (preferably close to monitor). Each side of theintake line should be inserted into the receivers on either side of the water trap. Secure tightly. Areplacement filter (P/N 0007-1656) for the water trap is available and is replaced by unscrewing the clearplastic cup of the water trap, pulling the filter directly out (do not unscrew), and inserting the new filter intoplace. Replace the cup of the water trap. If desired, an optional mounting bracket (0007-1657) may beused to secure the water trap in place.NOTE: The termination filter (P/N 3015-3420) or end-of-line water stop filter (P/ N 3015-5512) should be used, regardless of the presence of a wat er trap.IMPORTANT: Extreme or humid temperatures may cause water to condense in the tubes.A water trap is highly recommended for use in these scenarios.