Programmer Parameters4-20 mA ParametersOTEE:N These parameters apply to the HR-E LCD 4-20 encoderThe 4-20 mA Parameters field (Figure 29) displays the parameters of the encoder analog control signal The 4-20 mA outputsignal is directly proportional to the meter rate of flow For default measurement resolution values, see the MeasurementResolution charts in the High Resolution LCD Encoder User Manual, available at www.badgermeter.comFigure 29: 4-20 mA Parameters• The 4 mA field is always set to zero (0) The register produces a 4 mA signal at zero flow• The 20 mA Setting field displays the flow rate setting Set this parameter to the flow rate at which the output shouldgenerate to maximum signal In most cases, this is the maximum flow rate of the meter• The Damping Factor is the value used to stabilize the analog output signalPage 17May 2018 ENC-PM-02040-EN-03