FLOOR MODEL GAS DECK OVEN SERVICE MANUAL15TROUBLESHOOTINGPROBLEM POSSIBLECAUSEREMEDYNo Pilot No Gas Gas supply shut-off.Shut-off valve in “OFF” position.Kink in supply tube from valve. Inspect entire lengthBlocked supply lineFaulty valveDirty Orifice Make sure pilot orifice is clean and not blocked. Care must be taken to clean but not enlarge orifice hole.Pilot won’t stay lit Not Enough Gas Gas flow too low. Check gas pressureIncorrect orifice. LP orifice in place of Natural.Blocked Orifice in pilot. Check and clean as required.Flame too small Adjust pilot flameDirty Contact Jumper wire at thermostat posts on combination valve must be clean and tight.Thermopile must be clean and fastening nut tight to pilot bracket.FaultyComponentFaulty thermopile or thermocouple. See Thermopile Test Procedure.Faulty valve. Test for functioning Thermocouple or Thermopile. Change ValveMain Burner won’t light No Gas No pilotValve Shut-offBlocked supply lineFaulty Valve. Test gas flow before changing.Faulty Thermostat. Test gas flow before changing.Not enough gas Not enough supply. Test gas flow.Yellow or lazy flame Not enough air Adjust air mixture at inspiratorNot enough gas Test gas pressure/flowFlame lifting Too much air Adjust air mixture at inspiratorFlame flashes back High gaspressureTest gas pressure/flowFlame POPS when turned off Wrong orifice Verify and change as neededFlame too large Over gassed Test gas pressure/flowWrong orifice Verify and change as neededDelayed ignition Plugged burner CleanVentilation Consult HVAC professional to verify air mixtureOven takes too long to heat Not enough gas Test gas supply.Oven temperature TooHigh/Too LowThermostatsettingCalibrate thermostatVentilation Incorrect air flow can affect oven performance. Have checked by aBooster burner won’t light No gas Gas valve for booster burner shut-offBlocked supply lineNo electric No electric to ovenUnpluggedSwitch shut-offNo 24V to ignition module. Change transformerIgnitor failure Ignitor doesn’t light. Check voltage, change ignitorSoot in ignitor. Clean.Ignitor lights but doesn’t pass enough current to module. Change ignitorModule failure Module receives voltage but doesn't light ignitor. Change module.Module lights ignitor but doesn’t sense its current. Change module.Module receives current from ignitor but fails to open gas valve. Change module.Booster burner won’t stay lit No flame sense Sense rod missing ground connection. Clean and tighten.Soot on sense rod. Clean.Sense rod fails. Change sense rod.All technical problems should only be investigated byqualified gas fitters or service technicians. Improperadjustment, alteration or service can cause propertydamage, injury or death.For problems with your gas supply or oven operationcontact your gas supplier or contact a Bakers PrideAuthorized Service Agency.