5Feature DescriptionMotor Overload (I2t) with RMS Current Limit Provides motor overload protection which prevents motor burnout and eliminatesnuisance trips. UL approved as an electronic overload protector for motors.Electronic Inrush Current Limit (EICL™) Eliminates harmful inrush AC line current during startup.Short Circuit Prevents drive failure if a short circuit occurs at the motor (phase-to-phase).Regeneration Eliminates nuisance tripping due to high bus overvoltage caused by rapid decelerationof high inertial loads.Undervoltage and Overvoltage Shuts down the drive if the AC line input voltage is outside the operating range.MOV input transient suppression Prevents failure of power devices caused by voltage spikes in the AC line.Microcontroller Self Monitoring and Auto-Reboot.TABLE 3 – PROTECTION FEATURESTrimpotMinimum Speed (MIN) Sets the minimum motor speed.Offset (OFFSET) Sets the minimum motor speed.Maximum Speed (MAX) Sets the maximum motor speed.Acceleration (ACC) Sets the motor acceleration time (time to reach full speed).Deceleration (DEC/B) Sets the motor deceleration time (time to reach zero speed).Slip Compensation (COMP) Maintains set motor speed under varying loads.Boost (DEC/B) Sets the Volts/Hz Curve for 50 Hz motors to obtain maximum performance.Current Limit (CL) Sets the current limit and limits the maximum current (torque) to the motor.TABLE 4 – TRIMPOT ADJUSTMENTSAccessory DescriptionSignal Isolator and Run/Fault Relay(Catalog No. ID5SI-1)Provides isolation between a non-isolated signal voltage (0 to ±25 Volts DC)or current source (4 – 20 mA DC) and the drive. Mounts on the end of the drive. Thisoption is built-in on Catalog Nos. ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO.TABLE 5 – OPTIONAL ACCESSORYTABLE 6 – ELECTRICAL RATINGS*CatalogNo.AC Line Input Fuse orCircuitBreakerRating(Amps)Drive Output Net Wt.NominalVolts AC(50/60 Hz)Phase(φ)MaximumCurrent(Amps AC)OutputVoltage Range(Volts AC)MaximumContinuousLoad Current(RMS mps/Phase)MaximumHorsepower(HP (kW)) Lbs. kgID5202-CO 208/230 1 17.0 20 0 – 230 6.7 2 (1.5) 4.1 1.93 8.0 10ID5203-CO 1 208/230 3 10.8 15 0 – 230 9.0 3 (2.25) 4.6 2.1ID5401-CO 400/460 3 2.4 5 0 – 400/460 2.0 1 (.75) 4.1 1.9ID5402-CO 400/460 3 3.9 5 0 – 400/460 3.3 2 (1.5) 4.1 1.9ID5403-CO 2 400/460 3 5.3 10 0 – 400/460 4.6 3 (2.25) 4.1 1.9ID5405-CO 1,2 400/460 3 9.6 15 0 – 400/460 8.3 5 (3.75) 4.6 2.1Notes: 1. Catalog Nos. ID5203-CO, ID5405-CO contain built-in cooling fan. 2. Catalog Nos. ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO arerated 0 – 400 Volts AC for 50 Hz motor operation and 0 – 460 Volts AC for 60 Hz motor operation.*All models contain a Terminal Block for AC line and motor connections. The Signal Isolator and Run/Fault Relay is standard on Catalog Nos.ID5401-CO, ID5402-CO, ID5403-CO, ID5405-CO and optional on Catalog Nos. ID5202-CO, ID5203-CO.